48
Rinnai Corporation
V3237 Models
INSTALLATION CHECK LIST
1) Is gas pressure at product correct? Check the in coming gas pressure at the test
point on the gas inlet. Refer to gas pressure check list page for the appropriate
pressures.
2) Check for water and gas leaks. Use soapy water to test for gas leaks.
3) Turn Power on.
4) Open any hot water tap fully.
5) Check the operation of the unit. Check the operation of each of the remote
controller(s).
6) Explain the proper operation of the Rinnai Water Heater to the customer.
Water Temperatures over 125°F can cause
severe burns instantly or death from scalds.
Hot Water can cause first degree burns with
exposure for as little as:
3 seconds at 140 °F
20 seconds at 130 °F
8 minutes at 120 °F
Test the temperature of the water with your
elbow before placing a child in the bath or
shower.
Do not leave a child or an infirm person in
the bath or shower unsupervised.
BURN
A B O U T H O T W A T E R
The gas pressure may be low due to too little flow, too high an incoming
temperature, and/or undersized gas piping. Examine these areas before
determining that the pressure needs to be adjusted.
Contact Rinnai before
adjusting manifold pressures at 1-800-621-9419. Failure to contact Rinnai
could void unit’s warranty.
U273-430(00).indd 48
06.2.8 10:37:10 AM
Summary of Contents for C98e
Page 36: ...36 Rinnai Corporation V3237 Models PRODUCT DIMENSIONS INDOOR UNIT ...
Page 42: ...42 Rinnai Corporation V3237 Models RECOMMENDED PIPING FOR BASIC INSTALLATION ...
Page 44: ...44 Rinnai Corporation V3237 Models OPTIONAL PIPING FOR CIRCULATION SYSTEMS ...
Page 52: ...060 00012 30082 6 U273 430 ...