Simulation feed forward and feedback
MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
Wireless controller (with transceiver): MC-502RC-1US-MS (optional)
Non-polarized two-core cable
•
Flame failure - Flame Rod
•
Boiling protection
•
Combustion fan rpm check
•
Over current - glass fuse (3 amp)
•
Top of heater - 6 inches
•
Front of heater - 6 inches
•
Sides of heater - 2 inches
•
Top of heater - 2 inches
•
Front of heater - 6 inches
•
Sides of heater - 1/2 inches
Natural Gas: min 6” W.C.
max 10.5” W.C.
Propane Gas: min 10” W.C.
max 13.5” W.C.
Natural Gas: high fire 3.7” W.C. low fire 0.77” W.C.
Propane Gas: high fire 4.2” W.C. low fire 0.93” W.C.
Meets California and Texas NOx Emission Rules
Commercial only; heat exchanger 5 years*; all other parts 5 years*;
labor 1 year; (* 3 years if used as a circulating water heater within a
circulation loop, when the water heater is in series with a circulation
system and all circulating water flows through the water heater)
•
Remaining flame (OHS)
•
Thermal fuse
•
Automatic frost protection
•
Back of heater - 0 inches
•
Bottom of heater - 12 inches
•
From vent pipe - 0 inches
•
Back of heater - 0 inches
•
Bottom of heater - 12 inches
•
From vent pipe - 0 inches
Water Temperature Control
Remote Controls
Remote Control Cable
Safety Devices
Clearances from combustibles
(suitable for closet, attic, and
crawl space installations)
Clearances from non-combustibles
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
C53i (2520FFUC)
Rinnai Corporation
• 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
WEIGHT: 49 LBS