Rinnai Aspiration Radius Glass Brochure & Specs Download Page 2

As an example, you wish to purchase a Slimfire 25 flame fire, live in the ‘Cool’ zone, 
and have an area to heat of 65m

2

. The recommended ‘Heats up to’ capacity for this 

model is 68m

2

, however you also have no wall insulation and a house built on stumps. 

The heat loss total percentage is -15% (-7% + -8% = -15%) which is deducted from 
the 68m

2

 (the capacity of your heater) as a % to reduce it to 58m

2

. This will no longer 

heat your desired 65m

2

. The next model up is the Royale Manual Inbuilt with a ‘Heats 

up to’ capacity of 93m

2

, less the 15% heat loss = 79m

2

, which will adequately heat 

the area.

step 1

 climate

Pictured on the right is a climate map of 
Australia that shows four winter climate 
zones  relevant  to  Rinnai  Heaters; 
Mild,  Cool,  Cold  and  Very  Cold.  It  is 
important that you choose the correct 
zone  that  suits  your  application,  as  it 
directly  relates  to  the  performance  of 
your  heater.  Detailed  State  maps  can 
be found on the ‘heater selector’ page 
of our website: www.rinnai.com.au.

step 2 

heating area

It is also important that you consider the 
size of the heating area. This includes 
adjacent  rooms  through  permanently 
open  doorways  and  hallways.  In  this 
brochure,  on  the  back  page,  is  the 
approximate  maximum  area  that  the 
unit  will  heat  based  on  the  climate 
zones (ie. Step 1).

step 3 

heat loss

Not  all  homes  will  have  all  of  the 
features listed in the table to the right. 
Consequently, this will affect the heating 
capacity. Place a   alongside each of 
the design features if they are relevant 
to  your  home.  Everywhere  there  is  a 

,  an  adjustment  to  the  ‘Heats  up  to’ 

capacity will need to be made.

Please note that this is only a guide and 
individual house designs and locations 
may vary. 

Contact the Rinnai Helpline 
if you require further assistance 
1300 366 388.

www.rinnai.com.au

calculate on-line 
in 3 easy steps

Your area should be less than the Adjusted Capacity

Calculate your selected Rinnai Heater’s Capacity

1. Selected Heater

4. ‘Heats up 
to’ Capacity

(see back page)

2. Area/Zone

5. Less 
Heat Loss 

(see table below)

3. Total area you 
are going to heat 
(length x width)

6. Adjusted 
Capacity

m

2

m

2

m

2

%

 

Heat Loss Factors

      Deduct

Example

No Ceiling Insulation

-15%

______ %

No Wall Insulation

-7%

______ %

-7%

House built on stumps (not a slab)

-8%

______ %

-8%

No carpets on floors

-5%

______ %

No drapes on windows

-10%

______ %

Window area exceeding 15.0m

2

-15%

______ %

Ceiling area exceeding 2.4m

2

If Yes, height  2.5 - 2.8m

-3%

______ %

 

2.8 - 3.0m

-6%

______ %

 

3.0m +

-9%

______ %

Reversible Ceiling Fan (positive)

+5%

______ %

______ 

HEAT LOSS FACTOR

TOTAL

______ %

-15%

Summary of Contents for Aspiration Radius Glass

Page 1: ...FLAME FIRES FLAME FIRES...

Page 2: ...re on the back page is the approximate maximum area that the unit will heat based on the climate zones ie Step 1 step 3 heat loss Not all homes will have all of the features listed in the table to the...

Page 3: ...stellation 6 7 Traditional design open convector flame fire providing a nostalgic look but with inbuilt modern technology Royale ETR MANUAL 8 9 Classic design featuring both freestanding and inbuilt m...

Page 4: ...es unique to the Australian market the Aspiration embodies state of the art technology with great aesthetics These include full electronic thermostatic operation high efficiency heating utilising Rinn...

Page 5: ...thermostat and maintains a constant flame picture when you just want the ambience of a fire 3 Speed Fan For added comfort and even temperature distribution Inbuilt Zero Clearance Provides heat protec...

Page 6: ...ryear Rinnai have designed this open convector decorative fire with a choice of burn mediums and fascias which can be mixed and matched to your needs Complete with the latest electronic technology you...

Page 7: ...ion minimising potential mess or damage to the appliance Inbuilt Zero Clearance Provides heat protection to surrounding structures allowing greater flexibility and reduced installation costs Remote Co...

Page 8: ...D FLAME FIRES IN THE WORLD TODAY IT boasts many features unique to Rinnai as well as other standard features that others charge for as options IF available THE ROYALE MANUAL IS THE ULTIMATE IN EASY OP...

Page 9: ...MANUAL Benefits Inbuilt or Freestanding Configurations Depending on your installation requirements Powerful Heat Output An even spread of fan forced warm air throughout the room Electronic Ignition Pr...

Page 10: ...Complete with a slim line flat glass front and realistic flame and log appearance this contemporary flame fire is an easy way to upgrade the look of your existing living area or a great addition to a...

Page 11: ...novations Specifically designed to replace old 70 s space heaters the Slimfire rear flue usually enables a straight swap over The Slimfire is also great for older homes fitted directly into a masonry...

Page 12: ...ut anywhere whether a fireplace exists or not The Finishing Touch Before Build a Frame Slip in the Zero Box Drop in the Flue Plaster and Paint Height Width Depth Zero Box Order Code Royale Inbuilt 745...

Page 13: ...n packages are stocked and distributed by Rinnai Stockists Height Width Colour Order Code Inspiration Mantle 1150mm 1360mm Dark Cherry INSPMC Beech INSPMB Inspiration 3 sided Fascia 970mm 970mm Duraco...

Page 14: ...ND x 2 ESCONDK ESWTKIT 4 Vertical On Wall Kit Co Ax Pipe 900mm Wall Terminal Kit ASPKIT03 ESPIPE900 ESWTKIT 5 Vertical On Wall Kit Co Ax Pipe 900mm Bend 2 x 45 Wall Terminal Kit ASPKIT03 ESPIPE900 ESB...

Page 15: ...in Flue 45 Twin Skin Offset 900mm Galvanised Flue Ext Twin Skin Order Code FLF0450M FLF0900M FLFBEND FLFEXT03 Inbuilt Accessories Flue Adaptor Plate 50mm Plinth 45 Twin Skin Offset 40mm Ext Top Surrou...

Page 16: ...mfire 25 Inbuilt 645 750 385 550 630 595 700 Min 360 Metallic Black 7 7 25 5 0 42 50 68 77 Stainless Steel 35 07_MAR Please note 240V power is required on all models A power cord and plug is fitted If...

Reviews: