RinKmo EI18 Installation And User Instructions Manual Download Page 6

8888

OPERATION INSTRUCTIONS

TROUBLESHOOTING

Power indicator

Heating indicator

Temperature display

Knob

Power On

When the mains power supply is switched on, the buzzer 

beeps once and all the indicators light up for three 

seconds and then go out except power indicator. Power 

indicator is on green, heating indicator and display screen 

are not on.

Operation

1. Press the knob (a beep can be heard) to turn on the 

water heater power, the LED display will turn on, it shows 

the actual outlet water temperature. Heating indicator is on 

red in the state of heating. 

Note: 

The unit will not work and the heating indicator is not 

on if there is no water flow, or the water flow do not meets 

the start-up requirements (0.66GPM/2.5L/min). 

2. If the unit is frequently used and the intermediate 

interval is short, initially a short burst of very hot water from 

the unit will flow out, wait a few seconds for the water to 

cool down to the set temperature when using.

CAUTION:

 Regularly clean the inlet filter and the shower 

head to get enough flow.

PROBLEM ISSUE

POSSIBLE CAUSE

SOLUTION

Display E1 / E0

Display E2 / E3

Display LL

Inlet temperature 

sensor failure.

Inlet temperature lower 

than 37°F (3

)

Unit do not work when inlet 

temperature lower than 37°F (3

).

Display HH

Inlet temperature higher 

than 176°F (80

)

Unit do not work when inlet 

temperature higher than 176°F 

(80

).

Contact: 

[email protected]
Contact: 

[email protected]

1

Make sure that the main circuit 

breakers that supply the water heater 

is on

.

 

2

The unit may be wired error.

3

There may is a problem with the 

circuit breaker.

4

.

 Contact: 

[email protected]

Outlet temperature 

sensor failure.

1. Turn up the setting temperature.

2. Reduce water flow.

3. If the first installation occurs, 

please let the electrician check the 

wiring carefully. The wiring may be 

incorrect.

If not contact:

[email protected]

4. Check the power supply.

5. Replace temperature sensor.

6. Replace heating element.

Water leakage at the 

inlet and outlet 

connector.

1. The connector is 

not installed in place.

2. Seal damage.

1. Tighten the connector.

2. Replace the seal.

The unit does not 

work (Power 

indicator is NOT on)

Incorrect power wiring 

connection or no power.

Water heater is not 

heating at all (Power 

indicator is on)

Water heater is 

working but the outlet 

temperature is not 

hot well.

1. Low Setting temperature

2. Excessive water flow

3. Faulty wiring

4. Voltage too low.

5. Temperature sensor 

failure.

6. Heating element 

damaged.

1. Turn down the setting temperature

2. Increase water flow

3. Cut off the power and contact:       

[email protected]

Water heater is 

heating but the outlet 

temperature is too 

hot.

1. Temperature set too high.

2. Low water flow

3. PCB failure

Clean them

The outlet flow is 

reduced.

Inlet filter,shower or faucet

clogged.

1. No water flow.

2. The flow too small to start 

up the unit.

3. Control board failure.

1a. Check the water supply channel;

1b. Clean filter at unit; 

1c. Clean faucet aerator or shower 

head.

2. Increase water flow.

3. Cut off the power and contact:  

     [email protected]

Temperature Control

In the state of heating the outlet water temperature can be 

adjusted by turning the knob. Turn the knob clockwise to 

increase the outlet temperature, and turn the knob coun

-

terclockwise to decrease the outlet temperature between 

80°F – 140°F (26

- 60

), the factory set temperature is 

95°F

.

When the setting temperature is turned to the maximum or 

minimum, it will be not changed and two beeps will be 

heard at the same time.

Fahrenheit / Celsius Switch 

●The factory set temperature of the unit is Fahrenheit.

● In the state of heating, press the knob for 3 seconds, the 

display will switch between Fahrenheit and Celsius.

● When fahrenheit is displayed, the last text shows F.

● When celsius is displayed, the last text shows C. 

35C

95f

Fahrenheit display 

Celsius display 

NOTE: 

When  the outlet water temperature reaches 167°F 

(75

℃) 

the unit will stop heating.

Summary of Contents for EI18

Page 1: ... understand the installation and safety manual thoroughly and carefully The manual contains important safety tips and instructions INSTALLATION AND USER INSTRUCTIONS TANKLESS ELECTRIC WATER HEATERS READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner EI18 EI24 Model 8888 ...

Page 2: ...appliance basic safety precautions should always be followed DO NOT install this unit in a location where it may be subject to freezing temperatures If the water inside your tankless water heater freezes it can cause severe and permanent damage that is not covered under your warranty Water temperature over 125 F 52 C can cause severe scalding If the set temperature of the unit is too high there is...

Page 3: ... be installed in the vertical position of the water pipe joint This unit has more than one power supply connection point Disconnect all power supplies before servicing WARNING To avoid damage the unit needs to be kept dry Keep unit away from direct sunlight moisture dust steam and other liquids WARNING The unit do not installed in places with water leaks such as under air conditioning lines that m...

Page 4: ...roved vacuum breaker or other such method as proved effective by test WARNING Pipe dope or PVC CPVC primer and glue is not allowed to used on the threads of the outlet and inlet fittings These chemicals can damage the nipples and cause leaks Only thread sealing tape can be used SUGGESTION To avoid the property damage caused by leakage small probability event the machine needs to be installed in pl...

Page 5: ...circuit and damage the circuit board make sure all strands are secure inside the terminal block L2 connector L1 L2 L1 L2 L1 R1 R3 G R2 heating element heating element heating element PCB 3 PCB 3 PCB 3 PCB 1 thermal cut out thermal cut out thermal cut out t0 t1 flow sensor temperature sensor PCB 2 triac triac triac EI18 EI24 L2 connector L1 L2 L1 heating element heating element R1 G R2 PCB 3 PCB 3 ...

Page 6: ... service outlook com 4 Check the power supply 5 Replace temperature sensor 6 Replace heating element Water leakage at the inlet and outlet connector 1 The connector is not installed in place 2 Seal damage 1 Tighten the connector 2 Replace the seal The unit does not work Power indicator is NOT on Incorrect power wiring connection or no power Water heater is not heating at all Power indicator is on ...

Page 7: ...pper Min Water Flow Water connection Watts Temp Rise EI18 Model 1 5GPM 2 25GPM 3 0GPM 3 4 NPT 208V 240V 208V 240V 2x38A 2x33A 18 0kW 13 5kW 80 54 40 60 40 30 0 66GPM 2 5L min Working pressure 150PSI 10BAR 2x8AWG EI24 3x34A 24 0kW 92 73 54 3x29A 18 0kW 80 53 40 3x8AWG Voltage ...

Page 8: ...Cod 0020300897 rinkmo service outlook com ...