RECYCLING

This marking indicates that this product should not be disposed with 
other household wastes throughout the 2012/19/EU. To prevent possible 
harm to the environment or human health from uncontrolled waste 
disposal, recycle it responsibly to promote the sustainable reuse of 
material resources. To return your used device, please use the return 
and collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

MAINTENANCE INSTRUCTIONS

This charger requires minimal maintenance. As with any appliance or tool, a few common sense rules will prolong the life of the 
battery charger.
ALWAYS BE SURE THE CHARGER IS UNPLUGGED BEFORE PERFORMING ANY MAINTENANCE OR CLEANING.
1. Store in a clean, dry place
2. Coil up the cords when not in use.
3. Clean the case and cords with a slightly damp cloth.
4. Clean any corrosion from the clamps with a solution of water and baking soda.
5. Examine the cords periodically for cracking or other damage and have them replaced if necessary.
6. 

WARNING

: All other service should be done by qualified personnel only.

TECHNICAL DATA

Model RSC404 
Input 

220 - 240V AC 50Hz

Output 

6V DC 2A   12V DC 2/4A

Error code

Condition

Possible Cause

Solution

Er1

The battery voltage is less than 0.5V 
before charging.

The battery is defective.

Replace the battery.

The charge does not begin.

The battery clamps are disconnected 
with the battery. The battery clamps 
are connected to each other.

Connect the battery firmly and 
correctly.

The battery voltage is not matched 
with the selected mode.

Confirm that battery voltage is 
matched with the mode.

Er2

The battery voltage is 0.5V - 1.5V 
before charging.

The battery is defective.

Replace the battery.

The battery voltage is less than 11V 
after 4 minutes of charging. The bat-
tery is not full charged after 24-hour 
charge.

The battery is defective.

Replace the battery.

A load may be connected to the 
battery.

Disconnect the load and attempt to 
charge again. 

The charge current is too low.

Select a higher charge rate.

The battery voltage is less than 12V 
in 2 minutes after full charged.

The battery is sulphated beyond 
reconditioning.

Replace the battery.

Er3

The temperature of the charger is 
too high.

High ambient temperature.

Ensure adequate ventilation. The 
charger will resume charging after 
cooling.

TROUBLESHOOTING ERROR CODES

Summary of Contents for RSC404

Page 1: ...Instructions Intelligent Battery Charger 6V 12V 4A Suitable for 12V Lead Acid Gel Calcium AGM and EFB batteries between 10 120Ah...

Page 2: ...c shock unplug charger form outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk 12 WARNING RISK OF EXPLOSIVE GASES a WORKING IN VICINITY OF A LEAD ACID...

Page 3: ...or the 6V batteries 5 12V will appear when selecting the charge for the 12V batteries 6 The icon will indicate the charging process 7 The numbers or characters will indicate the battery voltage or the...

Page 4: ...sheet metal body parts Connect to a heavy gauge metal part of the frame or engine block OPERATING INSTRUCTIONS PREPARING TO CHARGE a If necessary to remove battery from vehicle to charge always remove...

Page 5: ...into an outlet that is properly installed in accordance with all local codes and ordinances DANGER Never alter AC cord or plug provided if it will not t outlet have proper outlet installed by a quali...

Page 6: ...Stage 8 Recondition When it is fully charged and low to 12 8V within 2min the charger will judge automatically Stage 9 Restoring The charger monitors a fully charged battery automatically If the batt...

Page 7: ...arge Reconditioning Function may help reverse the effects of sulphation and restore a batteries ability to accept a charge If the charger detects a sulphated battery it will automatically activate Bat...

Page 8: ...racking or other damage and have them replaced if necessary 6 WARNING All other service should be done by quali ed personnel only TECHNICAL DATA Model RSC404 Input 220 240V AC 50Hz Output 6V DC 2A 12V...

Reviews: