Replace the Bin Present Sensor or the Bin Full Sensor on a Rimage 5300N 

 

© 2007, Rimage Corporation 

2000516_A 

Replace the bin present sensor 

1. Remove 

the 

Torx T10 screw

 (Qty. 1) securing the 

bin present sensor to the bracket. 

2. Remove 

the 

bin present sensor

.

 

 

3.  Position the replacement 

bin present sensor

 on the 

bracket. 

4.  From the top of the sensor, insert the 

Torx T10 

screw

 (Qty. 1) to secure the sensor to the bracket. 

 

Bin Present Sensor 

Replace the bin full sensor 

1. Remove 

the 

Torx T8 screw

 (Qty. 1) securing the bin full 

sensor to the bracket.

 

 

2. Remove 

the 

bin full sensor

3.  Position the replacement 

bin full sensor

 on the bracket. 

 

Notes: 

Bin Full Sensor 

 

 

The sensor is on the opposite side of the bracket as 
the bin present sensor. 

 

The sensor is positioned so that the screw is 
inserted into the hole with the raised edge. 

4. Insert 

the 

Torx T8 screw

 (Qty. 1) to secure the sensor to the 

bracket. 

 

Raised Edge 
and Screw 

Reassemble the 5300N 

1. Connect 

the

 cables

 (Qty. 2) to the sensors.

 

 

 

2. Position 

the 

sensor bracket

 over the studs on the frame. 

 

3.  Secure the sensor bracket with the 

nuts 

(Qty. 2). 

 

4. Connect 

the 

power cord

5. Run 

diagnostic test 6 – Sensors diagnostic test

. More information on diagnostic tests is available in your 

5300N user guide. 

 