Rimage Professional™ 3400 and 5400N Diagnostic Tests
2001497_A
7
6.
Check the position of the carousel.
Note:
When the carousel is positioned correctly, the disc should not touch any part of the carousel.
a.
Manually, lower the
lift arm
and attached disc all the way into bin 1.
•
If the disc touches the carousel at any point, adjust the default carousel position.
•
If the disc does not touch the carousel, the default carousel position does not need to be
adjusted. Continue to
step 7
b.
Adjust the default carousel position.
•
Press
button 1
to raise the position measurement displayed on the operator panel. The carousel
adjusts its position to match the measurement.
•
Press
button 2
to lower the position measurement displayed on the operator panel. The carousel
adjusts its position to match the measurement.
c.
Repeat
until the carousel position is adjusted correctly.
7.
Press and hold
button 1
and
button 2
for three seconds to save the carousel position measurement.
The lift arm drops the disc into carousel bin 1 and the autoloader automatically begins to take the
following measurements:
Carousel bin top measurement
•
The autoloader measures the distance between the top of the lift column and the top edge of the
carousel.
•
The operator panel displays
[03 CAL CAR TOP O: XXXXX N: XXXXX]
.
Tip:
O: XXXXX is the old carousel top measurement, and N: XXXXX is the new carousel top
measurement, based on the current position of the carousel.
Carousel bin bottom measurement
•
The autoloader measures the distance between the top of the lift column and the bottom of the
carousel.
•
The operator panel displays
[03 CAL CAR BOT O: XXXXX N: XXXXX]
Tip:
O: XXXXX is the old carousel bottom measurement, and N: XXXXX is the new carousel bottom
measurement, based on the current position of the carousel.
Gripper plunger length measurement
•
The lift arm moves into bin 1 and begins picking and dropping the disc. This cycle continues several
times and the autoloader calibrates the lift arm.
•
The operator panel displays
[03 CAL GRIPPER 0: XXXXX N: XXXXX]
Tip:
O: XXXXX is the old lift arm measurement, and N: XXXXX is the new lift arm measurement.
•
The autoloader automatically exits diagnostic test 3 and returns to diagnostic test mode. The
operator panel displays