Rimage Professional™ 3400 and 5400N Diagnostic Tests
2001497_A
1
Diagnostic Tests for the Rimage
Professional™ 3400 and
5400N
This document provides the information needed to access, select and perform all diagnostic tests for the
Rimage Professional 3400 and 5400N. The term “autoloader” is used throughout this document to refer to
these products.
Important!
Make sure that the autoloader is not in an error sate before you perform any of the diagnostic
tests. For information about operation and maintenance of the autoloader, refer to the
Professional 3400
and 5400N User Guide
.
Access and Select Diagnostic Tests
Access Diagnostic Mode
1.
Power on the
autoloader
.
2.
Allow the system to initialize. This may take several minutes.
3.
Open the
front door
.
4.
Remove any
discs
from the autoloader.
5.
Press and hold the
rotate carousel button (button 1)
until
[00 CHOOSE DIAGNOSTIC]
displays on the
operator panel.
Note:
Other status messages display on the operator panel while button 1 is being held in. Do not
release the button until the operator panel displays
[00 CHOOSE DIAGNOSTIC]
.
6.
Release
button 1
. The autoloader is in diagnostic mode.
Select a Diagnostic Test
1.
Once in diagnostic test mode, press
button 1
the same number of times as the test number (indicated in
the test title).
2.
Hold
button 1
in on the last press for five seconds, or until a new message displays. Release the button to
start the selected test.
For example:
To start diagnostic test 3 (calibration diagnostic), press
button 1
three times and hold it in
on the third press for five seconds, or until the operator panel displays
[03 CAL LIFT LEN 1 DISC IN BIN 1]
.
Tip:
To display each diagnostic test number and name, press button 1 at a rate that is slow enough to
read the test on the operator panel. If you pass the desired diagnostic test, release button 1 and wait
for the operator panel to display
[00 CHOOSE DIAGNOSTIC]
.
Button 2
Button 1
Operator Panel
Control
Panel