10
ASSEMBLY
FIG. 11
FIG. 10
FIG. 9
4. Install the straight Support Pipe (#5) with the
attached Intake Funnel through the connection end of
the ‘L’ pipe support. Attach the hose to the back end
of the funnel with the 4” hose clamp. Figure 9.
This adjustable positioning system allows the intake
funnel to be raised, lowered or swung away from the
collector housing to set it where needed to collect
dust and chips from your operating machines or hand
work. See cover photo or Parts Diagram on page 12.
NOTE:
By reversing or removing the straight support
pipe in the ‘L’ support, the funnel can be positioned
down to the floor for use when sweeping up debris!
Figure 10.
THE MACHINE MUST NOT BE
PLUGGED IN AND THE POWER SWITCH MUST BE IN
THE OFF POSITION UNTIL ALL ADJUSTMENTS ARE
COMPLETE.
INSTALL THE VERTICLE SUPPORT ASSEMBLY -
CONTINUED
INSTALL THE WALL MOUNTING BRACKET FOR
HANGING THE DUST COLLECTOR FOR USE
The 60-105 Portable Dust Collector includes a bracket
for mounting the collector onto a wall for dedicated
use to a machine, work area, bench, or for storage.
NOTE:
For permanent wall mounting, the casters do
not have to be installed onto the dust collector.
If casters have been installed on the dust collector,
check to make sure that the casters do not interfere
with the hanging of the collector on the bracket. A
spacer, or backing board may be necessary to be be
installed behind the mounting bracket to increase the
distance behind the bracket to allow for the casters.
INSTALL THE MOUNTING BRACKET
Position the Mounting Bracket (#38) on a sturdy wall
at a height for the dust collector’s bag to freely hang
down without harm, by an electrical outlet so that an
extension cord is not used, and near a machine(s) so
that a long dust hose is not need which can reduce
the suction efficiency of the dust collector.
1. Once the position of the bracket on a wall is deter-
mined, use a pencil to mark the wall with the locations
of the 3 holes in the mounting plate. If possible, locate
the center hole where there is a stud.
2. For solid, plywood or masonry walls, fasteners can
be used to directly attach the plate to the wall. For
wallboard, the use of molleys are recommended.
3. The plate’s outer 2 holes are for the Phillips
Screws (#37), the center hole for the large Hex Screw
(#36). Figure 11.
CONTINUED ON PAGE 11
FUNNEL ON
FLOOR FOR
SWEEPING
WALL MOUNTING BRACKET & FASTENERS