Remove the two cleaning lids�
Lift the top baffle plate up�
Vacuum the combustion residues with a vacuum cleaner�
Now clean the lateral flues with the supplied brush�
Remove the two cleaning lids�
Vacuum the combustion residues off the flue gas duct, especially
the areas to the case of the fan�
Install the removed parts in reverse order again�
Note
Your stove may suck in false air via incorrectly sealed cleaning
covers; this air may lead to incomplete combustion in the fire
trough and thus piling up of pellets� DANGER of FIRE!
To ensure the proper operation of your combination stove, replace
the defect (porous, frayed) seals after cleaning and maintenance�
Cleaning the flue gas channels
annually
Remove the flue pipes� Inspect and clean chimney connection� Brush
off any soot and dust deposits in the fire and in the flue pipes and
vacuum�
Note
Accumulated fly ash in the flue gas channels may impair the
performance of the stove and pose a safety risk�
Checking door seal
annually
The condition of the seals at doors and glass should be checked at
least once a year� Repair or replace seals depending on condition�
Note
Only intact seals ensure your stove works perfectly�
Bearings
annually
All built in bearings (pellet screw, turning grid) should be checked�
Clean or replace bearings depending on condition�
#13