8. BURNBACK AND FLUE GAS FLAP
Start of operation
Once the stove has been reconnected to the mains you see the
following warning on the display�
Pull Down Lever
WARNING
BURNBACK AND
FLUE GAS FLAP
The stove cannot be taken into operation as long as the burnback
flap is not pulled out and the flue gas flap is not closed yet�
The burnback flap must be pulled out using the handle supplied
until it remains open�
Tip
The burnback flap can be pushed back in without problem due
to the special mechanism, the black galvanised shaft is thus no
longer visible from the outside�
Insert the handle of the flue gas flap into the stove� The handle must
then be shifted backwards to close the flap�
The warning is deleted as soon as the two flaps are activated and
the Home menu appears�
Refilling logs - opening flue gas flap
Attach the wrench in shown position�
Press the wrench inside�
+ 1cm
Turn the wrench as illustrated� The flue gas flap is now open�
Wait about 3 seconds before you open the combustion chamber
door to refuel�
Tip
If the flue gas flap is open, a warning appears on the display� It
expires when you close the flue gas flap�
Put one to two logs (max� 2�8 kg) on the embers�
After closing the combustion chamber door, turn back the wrench
into starting position�
1
2
Note
Pellet operation is not possible with an open flue gas flap�