RIKA Espirit Manual Download Page 3

 

 

AUSTROFLAMM:  AN OVERVIEW

 

 

Portrait

 

 

Congratulations on your purchase of a quality 
Austroflamm wood stove made by Rika.  You are now a 
member of a group of more than 100,000 Rika owners.  
If you were not familiar with Rika before your purchase, 
please allow us to introduce ourselves: 
 
Rika was founded more than 50 years ago in 
Micheldorf, Austria by Karl Riener and his family.  From 
a small company, specializing in hand made wrought 
iron products, grew a large, well known company 
recognized today as Rika Metallwarengesellschaft.  We 
appreciate quality and feel that our company 
manufactures some of the finest wood and pellet 
burning stoves available in today’s marketplace.   
 
Unique designs and emphasis on quality, performance 
and superior workmanship have made us a leading 
stove manufacturer in Europe.  State of the art 
processes, such as; robotic welding, laser cutting and 
complete micro-processor control systems, allow us to 
produce a final product that we feel is unequalled. 
 
In addition to wood stoves, we are also known for our high quality pellet stoves, wood-burning 
cook stoves, freestanding fireplaces, and water heater units.  Rika also produces a large 

variety of other metal products for 
international corporations.   
 
In 1988, Rika began to introduce its 
products into the United States under 
the trade name Austroflamm.  Rapid 
growth in the U.S. is directly attributed 
to the quality and unique design of the 
Austroflamm line of stoves.   
 
Thank you for your purchase. 
 
 
 

Summary of Contents for Espirit

Page 1: ...1...

Page 2: ...ove Tested and Listed by OMNI Test Laboratories Inc Beaverton Oregon SAFETY NOTICE IF THIS WOOD STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY AND TO REDUCE THE RISK OF FIRE F...

Page 3: ...toves available in today s marketplace Unique designs and emphasis on quality performance and superior workmanship have made us a leading stove manufacturer in Europe State of the art processes such a...

Page 4: ...annual basis HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY FROM STOVE DO NOT TOUCH ANY RADIANT SURFACE OF YOUR STOVE CONTACT WITH STOVE MAY CAUSE SKIN BURNS DO NOT COOK FOOD HOT BEV...

Page 5: ...ve heat output could exceed design and safety limits of the appliance This may result in damage to the appliance a house fire other personal property damage personal injury or death DO NOT OPERATE YOU...

Page 6: ...n the general vicinity of the stove If fumes become excessive open a windows and or door and use a room fan to create cross ventilation Hardening of the finish will be complete after several hours of...

Page 7: ...7 OMNI SAMPLE LABEL FOR ESPRIT FREESTANDING WOOD STOVE...

Page 8: ...8 EPA CERTIFICATION INFORMATION...

Page 9: ...Z21351 shaker grate 4 108687 screw for shaker grate 5 Z28458 shaker grate actuator 6 Z20467 shaker grate lever 7 B15687 tiered baffle system 8 L00853 upper fire brick holder left 9 L00852 upper fire...

Page 10: ...205 fire brick left side 18 Z20215 fire brick left base 19 Z20216 fire brick left rear 20 Z20216 fire brick right rear 21 Z33205 fire brick right side 22 Z20215 fire brick right base 23 Z20214 fire br...

Page 11: ...CSA CAN B365 Installation Code for Solid Fuel Burning Applications and Equipment These standards are the basis for many national codes They are nationally recognized and are accepted by most local aut...

Page 12: ...5 16 13 18 all clearances are in inches ALCOVE CONFIGURATION Connector Pipe A B C D E F Double Wall 64 30 24 5 16 10 10 5 Single Wall 72 38 24 5 16 17 17 5 all clearances are in inches TOP VENT OUT T...

Page 13: ...5 16 24 5 16 na na all clearances are in inches REAR VENT OUT THE BACK Connector Pipe A B C D E F Double Wall na 8 24 5 16 na na Single Wall na 10 24 5 16 na na all clearances are in inches REAR VENT...

Page 14: ...ire stops where needed or required insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer and or local building codes The chimney...

Page 15: ...sure that the sections do not separate For best performance the chimney connector should be as short and direct as possible with no more than two 90 elbows The maximum horizontal run is 36 and a recom...

Page 16: ...HIMNEY CONFIGURATIONS There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall NFPA Standard 211 allows the following wall pas...

Page 17: ...e liner See METHOD A diagram 2 Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section with insulation of 1 25 4 mm or more build a wall pass through with a minimum 9 228 6 m...

Page 18: ...ure the metal chimney connector do not penetrate chimney flue liner See METHOD C diagram 4 Start with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4...

Page 19: ...nnected to a masonry chimney except for Method B must extend through the wall pass through system to the inner face of the chimney flue but not beyond It does not have to be fastened in place as long...

Page 20: ...tial chimneys must be enclosed where they extend through closets storage areas or habitable spaces where the surface of the chimney could come into contact with people or combustible materials Chimney...

Page 21: ...t A short hot fire will help clean off much of the normal soot buildup Using dry well seasoned firewood will help keep the glass soot free Fire Brick The firebox in your woodstove comes with a layer o...

Page 22: ...the stove should be avoided it is important to supply it with sufficient fuel to maintain a moderately hot fire This aids in reducing the buildup of creosote in the chimney and aides in minimizing so...

Page 23: ...vely cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ig nited this creosote makes an extremely hot fire The chimney and chimney connector shou...

Page 24: ...t material in your stove Do not use other type of gaskets If any gasket material in your stove needs to be replaced contact an authorized RIKA dealer for repairs To replace the gasket make sure the fi...

Page 25: ..._______________ ______________________________________________________________________________________ ______________________________________________________________________________________ __________...

Page 26: ...d date of installation 4 Serial number of the stove 5 Nature of defect malfunction or complaint Arrangements will be made for inspection If the inspection indicates that the failure was due to defecti...

Page 27: ...warranty coverage For your convenience a warranty registration card similar to the one pictured in the example on this page is provided for registering the purchase of your new wood stove The actual w...

Page 28: ...28...

Reviews: