6. MANUAL OPERATION

Each  combustion  process  needs  oxygen.  Before  ignition  the 
combustion chamber must be regularly cleaned from ash to ensure 
an adequate supply of air.

The right fill amount for heating up is 2 - 3 logs of the quantity given 
in AMOUNT OF FUEL.

Correct heating up primarily according to instructions counteracts 
excessive smoke during heating up.

RIKA firelighter

Always ignite the RIKA firelighter on the red tip. One block consists 
out of 8 ribs which can be divided to the desired size. The amount 
of  RIKA  firelighters  also  depends  on  the  size  and  humidity  of  your 
firewood. Ideally, one rib is enough to light up the fire.

Tip

You can order the RIKA firelighter with the number E15834 at your 
RIKA dealer.

Combustion air regulation

The  performance  of  your  stove  also  depends  on  the  chimney 
draught;  therefore  the  control  knob  for  combustion  air  regulation 
must be used according to your own experience.

Zero setting

Middel position

Heating up position

The heating-up position may only be used for heating up or refilling.

Note

The air control seals to 100%. Complete closing of the air regulator 
(zero setting of control knob)

 during operation

 poses a hazard of 

deflagration and is strictly prohibited.
A  stop  to  prevent  inadvertent  closing  of  the  air  intake  has  been 
integrated for safety reasons.

If the stove is not in use, warm air can release through the chimney. 
The Zero position of the control knob can prevent this. To prevent air 
intake  completely,  the  control  knob  must  be  pressed  back  slightly, 
only then the zero position can be set and the air regulator thus be 
closed. 

Summary of Contents for BACK

Page 1: ...Operating manual BACK...

Page 2: ...p 9 3 BRIEF INFORMATION ON COMBUSTIBLE LOGS 10 Suitable fuels and fuel amounts 10 Wood types 10 Output controlling 10 Clean combustion 10 4 INSTALLING THE STOVE 11 General information 11 Connection to...

Page 3: ...ation 15 Cleaning the combustion chamber 15 Empty the ash drawer 15 Cleaning painted surfaces 15 Cleaning the door glass 15 Cleaning the oven 15 Cleaning the convection air openings 16 Combustion air...

Page 4: ...xploded diagram 1 2 3 6 5 4 5 11 10 9 15 20 21 21 28 27 30 17 22 23 24 25 110 26 19 19 18 20 18 8 12 33 10 14 32 7 13 16 31 29 47 48 49 50 51 52 46 35 36 37 39 40 34 38 44 40 41 42 45 53 46 43 57 55 5...

Page 5: ...5 EN 4 80 81 80 82 75 78 85 70 71 72 73 74 76 77 79 86 83 84 87 88 89 94 95 97 95 98 99 100 101 105 102 103 109 107 108 90 93 92 96 107 106 104 93 92 96 91 91 62 63 66 64 67 65 68 69 61...

Page 6: ...plate 58 Z37434 Shaft of soot remover 59 L03450 Mechanical soot remover 60 N111981 Hexagonal screw 61 L03467 Ash drawer 62 Z35812 Bottom plate 63 Z35813 Grate 64 Z37251 Fire brick left 65 Z37238 Defl...

Page 7: ...ange kW 4 8 Room heating capacity depending on house insulation m3 90 210 Fuel consumption kg h till 2 2 Efficiency 83 9 CO2 9 3 CO emission on 13 O2 mg mN 3 565 Dust emission mg mN 3 24 5 Exhaust g s...

Page 8: ...worn when post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no embe...

Page 9: ...ted with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney may...

Page 10: ...icularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type C...

Page 11: ...inspection door for regular inspection and cleaning must be present The flue pipe connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrou...

Page 12: ...rniture and stove panels Assembly dismantling panels Lift the top straight up Now loosen the hexagonal screws and tilt the side panel Subsequently lift the side panel to remove it Install the removed...

Page 13: ...er E15834 at your RIKA dealer Combustion air regulation The performance of your stove also depends on the chimney draught therefore the control knob for combustion air regulation must be used accordin...

Page 14: ...logs are well lit the control knob can be set one step further to zero position another few minutes later depending on draught and fuel quality amount Refilling After the first burn off add one or two...

Page 15: ...ut embers FIRE RISK Empty the ash drawer Empty the ash drawer regularly The ash drawer is simply pulled forward with the combustion chamber door open Cleaning painted surfaces Wipe the painted surface...

Page 16: ...u could vacuum out embers FIRE RISK Cleaning the flue pipes annually Remove the flue pipes Inspect and clean the chimney connection Brush off any soot and dust deposits in the fire and in the flue pip...

Page 17: ...h glass cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of bu...

Page 18: ......

Page 19: ...ser and installation manuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to...

Page 20: ...ypesetting and printing errors reserved 2017 RIKA Innovative Ofentechnik GmbH Z37363_Back_EN 13 09 2017 RIKA Innovative Ofentechnik GmbH M llerviertel 20 4563 Micheldorf AUSTRIA Tel 43 0 7582 686 41 F...

Reviews: