RIKA Ambia Operating Manual Download Page 10

Spare part overview article numbers

Nr. Art.Nr.

Description

1

Z37874

Door frame

B18563

Combustion chamber door assy

2

Z37059

Decorative glass

3

N112616

Round hollow seal D10

4

N112169

Hexagon socket screw

5

Z37644

Combusion chamber door

6

Z37621

Retaining plate

7

N111910

Allen screw

8

L03696

Panel secondary air

9

N111964

Hexagonal screw

10

N112614

Round sealing strip grey D13

11

N103693

Flat seal black 8x2

12

Z37060

Front door glass

13

L00475

Glass holder

14

L03601

Closure plate

15

L03602

Closure flap

16

N110586

Hexagonal countersunk screw

17

L03603

Handle Cold Hands

18

LB00766

Door opener

19

N112382

Hexagonal countersunk screw

20

Z37897

Angle support

21

N112438

Hexagonal countersunk screw

22

N105378

Hexagonal nut

23

N112522

Locking pin

24

Z28059

Spacer

25

L03589

Bottom guidance

26

N112051

Hexagonal screw

27

N112415

Hexagonal screw

28

N112269

Washer

29

Z38225

Spacer

30

L03588

Lock for telescopic rail

31

B18561

Telescopic rail right

32

N111964

Hexagonal screw

33

L03590

Top guidance

34

L03695

Washer

35

N112140

Hexagonal screw

36

L03616

Lock for chain

37

N108486

Allen screw

38

N112526

Chain

39

N111747

Ball bearing

40

B18566

Gear shaft

41

B18562

Telescopic rail

42

L03599

Hinge plate

43

N109718

Allen screw

50

Z37860

Bottom firebrick lining, front left

51

Z37862

Wood retainer

52

Z37641

Bottom plate

53

Z37642

Grate laterally

54

Z37072

Bottom firebrick lining laterally

55

Z37071

Bottom firebrick lining rear

56

Z37805

Firebrick lining rear

57

Z37803

Firebrick lining left

Nr. Art.Nr.

Description

58

Z37825

Firebrick lining lateral

59

Z37824

Firebrick lining rear

60

Z37861

Firebrick lining rear middle

61

N112274

Hexagonal nut M05

62

Z37827

Firebrick lining cover left

63

Z37823

Firebrick lining cover left

64

Z37821

Firebrick lining cover

65

Z37822

Firebrick lining cover right

66

Z37826

Firebrick lining cover right

67

Z37804

Firebrick lining right

68

Z37643

Grate middle

69

Z37070

Bottom firebrick lining, front right

70

LB00765

Ash drawer

71

N111950

Hexagonal screw M05x10

72

L03582

Cover

80

N104718

Circlips D08

81

B18557

Pulley with steel cable

82

N106175

Hexagonal nut

83

N111965

Washer M05

84

N112476

Adjusting screw

85

N112475

Bowden cable housing

86

N111950

Hexagonal screw M05x10

87

B18558

Regulator assy

88

LB00764

Regulator handle

89

N111948

Hexagon socket screw

90

Z37407

Seal

91

Z37408

Seal

92

N103988

Hexagonal nut M06

93

B18556

Airbox with intake pipe socket

B18555

Airbox assy

100

LB00906

Bottom steel front

101

B18578

Cover left

102

B18579

Cover right

103

LB00746 

Top steel front

104

B18581

Side casing steel, left 

105

LB00747 

Side casing steel, top

106

Z38763

Angle support

107

LB00775

Cover frame

109

Z20556

Flue pipe connection black D150

110

Z37039

Blind cover black

111

N100474

Sealing cord black D08

112

Z38762

Cover panel rear

113

N106472

Self-tapping screw M05x10

114

N112185

Self-tapping screw M05x10

116

B18580

Side casing steel, right 

117

B18661

Side cover bracket left

118

Z37886

Hinge stop angle

119

N106472

Self-tapping screw M05x10

121

Z38178

Glass cover

122

B18577

Magnet

123

Z37887

Hinge stop angle

124

B18576

Side cover bracket

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

10

Summary of Contents for Ambia

Page 1: ...AMBIA Operating manual...

Page 2: ...safety information 14 First heating 14 Safety distances 14 Prior to set up 15 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 16 Suitable fuels and fuel amounts 16 Wood types 16 Output controlling 16 Clean co...

Page 3: ...3 2 EN 1 EXPLANATIONS TO SYMBOLS Important Note Useful Tip Manually Fragile...

Page 4: ...xploded diagram 5 10 12 11 13 7 3 2 1 7 4 4 4 4 4 6 6 7 7 20 20 21 21 23 22 22 18 19 8 9 9 14 15 16 17 39 40 39 37 36 31 25 33 24 24 26 26 32 32 26 41 32 32 42 43 43 42 25 33 24 24 26 30 29 28 27 30 2...

Page 5: ...69 50 55 54 54 61 64 64 65 63 59 59 58 58 60 56 56 66 62 67 57 52 72 71 70 53 53 68 51 91 90 93 81 84 84 80 83 83 82 82 92 85 85 87 88 89 86 86 84 84 82 82 5 4 EN...

Page 6: ...Steel casing 109 110 111 116 104 101 102 103 105 105 112 106 113 114 114 100 107...

Page 7: ...sing 131 126 130 135 136 137 124 119 119 138 138 137 129 119 139 131 131 127 130 130 135 135 135 136 136 136 137 137 137 132 129 117 124 123 123 118 118 119 119 119 119 119 127 126 128 121 125 133 134...

Page 8: ...Stone or concrete casing 171 170 172 161 162 169 165 166 163 166 160 164 164 173 175 168 174 174 167...

Page 9: ...ete casing 182 183 178 187 186 180 184 184 185 185 189 189 189 189 189 176 177 181 179 191 177 195 192 193 194 180 188 188 190 190 194 187 189 189 190 191 191 176 195 195 192 192 193 193 194 194 178 1...

Page 10: ...on 58 Z37825 Firebrick lining lateral 59 Z37824 Firebrick lining rear 60 Z37861 Firebrick lining rear middle 61 N112274 Hexagonal nut M05 62 Z37827 Firebrick lining cover left 63 Z37823 Firebrick lini...

Page 11: ...37750 Side panel white stone bottom Z37791 Side panel concrete bottom 165 B18581 Side casing steel left 166 Z37755 Side panel soap stone top Z37756 Side panel white stone top Z37794 Side panel concret...

Page 12: ...temperature C testing Chimney draft requirement Pa 12 The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it...

Page 13: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 14: ...en post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall...

Page 15: ...rated with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney m...

Page 16: ...icularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type C...

Page 17: ...humidity of your firewood Ideally one rib is enough to light up the fire Tip You can order the RIKA firelighter with the number E15834 at your RIKA dealer Combustion air regulation The performance of...

Page 18: ...later depending on draught fuel quality and amount Refilling Note Use the handle Cold Hands or the RIKA heat resistant glove for every further addition of wood After the first burn off add one or two...

Page 19: ...ISK In a cold state dispose it of in the household waste Clean combustion chamber Note Only when the stove is cold You could vacuum out embers FIRE RISK The combustion chamber must be regularly cleane...

Page 20: ...Clean flue gas outlet annually Remove the flue pipes Inspect and clean the chimney connection Brush off any soot and dust deposits in the stove and in the flue pipes and vacuum 1 2...

Page 21: ...formance of the stove and pose a safety risk Check seals annually Check the condition of the seals at least once a year Repair or replace seals depending on condition Note Only intact seals ensure you...

Page 22: ...ss cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of burning...

Page 23: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Page 24: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z38218_AMBIA_EN 6 10 2021 RIKA Innovative Ofentechnik GmbH M llervie...