8. MANUAL OPERATION

Operating the riddle grate

(only stoves with riddle grate)

The ash is moved from the combustion chamber to the ash drawer 
by pushing the riddle grate handle back and forth� This frees the way 
for the primary air intake which is necessary for heating up�

In general the riddle grate should stay open� The air regulation is 
made completely with the control knob at the rear wall�

Combustion air regulation

The performance of your stove also depends on the chimney 
draught; therefore the control knob for combustion air regulation 
must be used according to your own experience�

Heating-up 

position

Middle position

Zero setting

The “heating-up position“ may only be used for heating up�

Note

The air control seals to 100%� Complete closing of the air regulator 
(zero setting of control knob) during operation poses a hazard of 
deflagration and is strictly prohibited�
A stop to prevent inadvertent closing of the air intake has been 
integrated for safety reasons�

If the stove is not in use, warm air can release through the chimney� 
To prevent air intake completely, the control handle behind the air 
control knob must be pulled to the front, only then the zero position 
can be set and the air regulator thus be closed� 

RIKA firelighter

Always ignite the RIKA firelighter on the red tip� One block consists 
out of 8 ribs which can be divided to the desired size� The amount 
of RIKA firelighters also depends on the size and humidity of your 
firewood� Ideally, one rib is enough to light up the fire�

Tip

You can order the RIKA firelighter with the number E15834 at your 
RIKA dealer�

Correct heating up

1� Push the control knob completely to “heating-up position”� Place 
left and right two small pieces of chipboard lengthways in the 
bottom of the combustion chamber�

Place two logs crossways on top of this chipboard�

2� Now place further pieces of chipboard in crosswise layers on top 
of the logs and place a firelighter on top of the chipboard� Some 
uncoated paper can be placed underneath the chipboard in case 
there is no firelighter available�

3� Now light the firelighter and close the combustion chamber door� 

Set the control knob for combustion air regulation to middle position 
some minutes later� 

If the logs are well lit the control knob can be set a step further to 
zero position another few minutes later (depending on draught and 
fuel quality / amount)�

Refilling

After the first burn-off, add one or two logs (see AMOUNT OF FUEL) 
to the blaze� Set the control knob to heating-up position again until 
the wood is well lit� Continue as defined in item 3�

For a optimal combustion with high efficiency and reduced emission 
it is necessary to place the control knob between middle position 
and zero setting�

Note

Sometimes a lot of smoke develops when wood is placed on a 
low firebed or when there is too less fresh air for combustion� An 
explosive gas/air mixture may arise and cause an eventual heavy 
deflagration� For safety reasons it is recommended to leave the 
combustion chamber door closed and press the control knob at 
the rear wall down completely into “heating-up position”� If the 
log wood is not igniting, start a new heating-up procedure after it 
stopped smoking�

Please proceed in the same way for every further addition of wood�

Summary of Contents for ALUMO

Page 1: ...ALUMO Operating manual...

Page 2: ...ng 12 Safety distances 12 Prior to set up 13 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 14 Suitable fuels and fuel amounts 14 Wood types 14 Output controlling 14 Clean combustion 14 6 INSTALLING THE STOV...

Page 3: ...surfaces 19 Checking seals 19 Cleaning the convection air openings 19 Combustion air intake 19 Cleaning the flue pipes 19 10 PROBLEMS POSSIBLE SOLUTIONS 20 Problem 1 20 Problem 2 20 Problem 3 20 11 G...

Page 4: ...2015 1186 Ecodesign Model Identifier Equivalent models ALUMO RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Othe...

Page 5: ...2021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Inno...

Page 6: ...el Identifier Equivalent models ALUMO 6 kW RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Other applied standard...

Page 7: ...2021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Inno...

Page 8: ...mN 3 851 Dust emission mg mN 3 19 Exhaust g s 7 2 Exhaust temperature C 180 Chimney draft requirement Pa 12 The owner of small firing systems or the person authorised for the small firing system is to...

Page 9: ...9 8 EN Spare part overview exploded diagram 36 34 38 37 33 35 40 32 32 41 31 30 39 10 16 23 19 22 28 8 9 5 6 7 17 18 19 20 21 8 1 2 3 4 11 12 13 14 15 9 27 25 26 24...

Page 10: ...63 63 52 65 64 62 62 59 60 61 58 57 57 67 60 61 66 54 51 56 56 53 50 55 75 76 74 72 70 71 73 77...

Page 11: ...35 L00618 Ash drawer 36 L00617 Ash drawer support 37 L00616 Grate arm 38 Z25948 Riddling disk 39 Z32940 Wood retainer black 40 Z32590 Firebrick lining rear 41 Z32592 Firebrick lining front left 50 Z34...

Page 12: ...e worn when post heating Q Use the heat resistant gloves supplied to open the doors of your stove Q Only use suitable tools from our range of accessories when handling embers and make sure that no emb...

Page 13: ...rated with the combustion chamber door closed Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney m...

Page 14: ...icularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type C...

Page 15: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Page 16: ...d all stove panels and stove attachments during any conversion work Select soft bases to prevent scratches to your living space furniture and stove panels Assembly disassembly stone Tilt the stone car...

Page 17: ...order the RIKA firelighter with the number E15834 at your RIKA dealer Correct heating up 1 Push the control knob completely to heating up position Place left and right two small pieces of chipboard le...

Page 18: ...nd chips may more than double the maintenance required Only use wood that has been stored properly and is dry and untreated Note Ash may contain embers only place ash in sheet steel containers FIRE RI...

Page 19: ...als at least once a year Repair or replace seals depending on condition Note Only intact seals ensure your stove works perfectly Tip You will find the sealing kit in the spare part overview Cleaning t...

Page 20: ...ss cleaner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solution s Q Wait to end of burning...

Page 21: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Page 22: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Page 23: ...23 22 EN...

Page 24: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z39003_Alumo_EN 22 12 2021 RIKA Innovative Ofentechnik GmbH M llervie...

Reviews: