Installation Guide 

 
 
 
 
 
 
 
 
 
 
 
 
 

RM-DS-1 Rackmount Kit 

                                                   

   

DS1000 Series, DS1000CA Series, DS1000E Series, DS1000D Series 

 

Digital Oscilloscope

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

May 2009 

RIGOL Technologies, Inc.

Summary of Contents for RM-DS-1

Page 1: ...RIGOL Installation Guide RM DS 1 Rackmount Kit DS1000 Series DS1000CA Series DS1000E Series DS1000D Series Digital Oscilloscope May 2009 RIGOL Technologies Inc...

Page 2: ...ogies Inc reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously correspondin...

Page 3: ...ctices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury or hazard that may immediately happen WARNING...

Page 4: ...Qty Part Number Description 1 1 Front Panel 1 RM DS 1 01 1 2 Support Board 1 RM DS 1 02 1 3 Left Plate 1 RM DS 1 03 1 4 Right Plate 1 RM DS 1 04 1 5 Rear Fixed Belt 1 RM DS 1 05 1 6 Rear Fixed Bracket...

Page 5: ...quirements must be fulfilled by the machine cabinet in which the instrument is mounted 1 The machine cabinet should be a standard 19 inch 2 At least 4U spaces 177 8mm have to be provided by machine ca...

Page 6: ...Name Description 1 Phillips screwdriver PH2 Phillips screwdriver CAUTION Only authorized personnel can perform the installation improper operation may cause damage to the instrument or incorrect inst...

Page 7: ...te fixed and fix them using six M4 bolts Figure 5 Installation of Front Panel 3 Place the instrument first put the instrument onto the support board and then generally slide it into right position dow...

Page 8: ...ix both the rear fixed brackets and rear fixed belt on the support board in connection with the instrument Figure 7 Fix the instrument 5 Loading into machine cabinet mount the rack with instrument fix...

Page 9: ...ng holes for rack Figure 9 Holes for rack 2 The rack has a power cord that was connected with the power input terminal and the power source terminal in series A ship type switch is used to turn ON or...

Page 10: ...all Tel 86 10 8070 6688 Fax 86 10 8070 5070 Service Support Hotline 800 810 0002 9 00 am 5 00 pm from Monday to Friday Or by e mail service rigol com Or mail to RIGOL Technologies Inc 156 CaiHe Villag...