Rigol DS8000-R Series Manual Download Page 11

Chapter 1 Disassembly and Assembly

                                                                                                                                RIGOL

 

DS8000-R Service Guide                                                                                                                                                                3

 

Table 1-1 Replacement Parts List 

No. 

Part No. 

Qty.  Name/Description 

2010004774 

Front Panel 

1020004713 

Rubber Keypad 

2010004764 

Probe Board 

2010004767 

Handle 

1020004722 

Metal Front Panel 

1020004724 

Hanging Ear 

1020003428 

M4x8 Torx Pan Head Screw 

1020004764 

Pad 

2010004757 

Main Board 

10 

1010002308 

BeCu Fingerstock (Slot Mount-4) 

11 

1020004721 

Fan Bracket 

12 

1020000573 

M3x20 Torx Pan Head Combination Screw 

13 

1020004765 

Fan Components 

14 

1020004720 

Metal Chassis 

15 

1010005871 

Power Cord Connector 

16 

1020004762 

Mylar Film 

17 

1010005841 

BeCu Fingerstock (Slot Mount-2) 

18 

1020004774 

23 

M3x6 Torx Flat Head Countersunk Screw   

19 

2010004759 

Interface Board 

20 

1020000619 

BNC Nut 

21 

1010006726 

SMA Cable 

22 

 

SMA Nut 

23 

2010003934 

Power Supply Board 

24 

1020004763 

Multiple-station Screw 

25 

1010006704 

Isolation Board 

26 

1020000571 

24 

M3x6 Torx Pan Head Combination Screw 

27 

1020004723 

Metal Cover 

 

 

The recommended disassembly procedures are as follows: 

Disassemble  the  Metal  Cover 

  Disassemble  the  Hanging  Ear 

  Disassemble  the  Front  Panel 

Assembly 

 Disassemble the Metal Front Panel 

 Disassemble the Probe Board 

 Disassemble the 

Fan  Components 

  Disassemble  the  Main  Board 

  Disassemble  the  Power  Supply  Board 

 

Disassemble the SMA Cable 

 Disassemble the Interface Board

 

 

Summary of Contents for DS8000-R Series

Page 1: ...Service Guide DS8000 R Series Digital Oscilloscope Jul 2020 RIGOL TECHNOLOGIES CO LTD...

Page 2: ......

Page 3: ...s subject to change without notice RIGOL shall not be liable for either incidental or consequential losses in connection with the furnishing use or performance of this manual as well as any informatio...

Page 4: ...operators Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting the in...

Page 5: ...of the instrument clean and dry Prevent Electrostatic Impact Operate the instrument in an electrostatic discharge protective environment to avoid damage induced by static discharges Always ground both...

Page 6: ...ss of important data Safety Terms on the Product DANGER It calls attention to an operation if not correctly performed could result in injury or hazard immediately WARNING It calls attention to an oper...

Page 7: ...con to enter the Utility menu first and then clicking the System menu item Content Conventions in this Manual DS8000 R series includes the following models Unless otherwise specified this manual takes...

Page 8: ...l Cover 4 Disassemble the Hanging Ear 5 Disassemble the Front Panel Assembly 6 Disassemble the Metal Front Panel 7 Disassemble the Probe Board 8 Disassemble the Fan Components 9 Disassemble the Main B...

Page 9: ...mbling the instrument Please use proper tools and follow the correct steps Take care not to deform the metal structure or get hurt when disassembling the metal structures To avoid causing damage to th...

Page 10: ...please follow the procedures and take care not to scratch the surfaces of the instrument This manual mainly introduces the disassembly and assembly methods for the DS8000 R series digital oscilloscop...

Page 11: ...er Cord Connector 16 1020004762 1 Mylar Film 17 1010005841 2 BeCu Fingerstock Slot Mount 2 18 1020004774 23 M3x6 Torx Flat Head Countersunk Screw 19 2010004759 1 Interface Board 20 1020000619 2 BNC Nu...

Page 12: ...ver Figure 1 1 Disassemble the Metal Cover Part Description 6 screws M3x6 torx flat head countersunk screw used for fastening the metal cover Disassembly Steps 1 Use the T10 screwdriver to remove 6 sc...

Page 13: ...e the Hanging Ear Part Description 6 screws M3x6 torx flat head countersunk screw used for fastening the two hanging ears not all screws are indicated in the above figure Disassembly Steps 1 Use the T...

Page 14: ...4 Disassemble the Front Panel Assembly Part Description 2 screws M3x6 torx flat head countersunk screw used for fastening the front panel assembly Disassembly Steps 1 Use the T10 screwdriver to remov...

Page 15: ...gure 1 5 Disassemble the Metal Front Panel Part Description 4 screws M3x6 torx pan head combination screw used for fastening the metal front panel Disassembly Steps 1 Use the T10 screwdriver to remove...

Page 16: ...obe Board Figure 1 6 Disassemble the Probe Board Part Description 5 screws M3x6 torx flat head countersunk screw used for fastening the probe board Disassembly Steps 1 Use the T10 screwdriver to remov...

Page 17: ...at head countersunk screw used for fastening the fan components Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the fan component 2 Take off the fan components gently Tip Wh...

Page 18: ...combination screw used for fastening the main board Disassembly Steps 1 Use the T10 screwdriver to remove 3 screws that secure the main board 2 Use the T10 screwdriver to remove 12 screws that secure...

Page 19: ...ndicated in the above figure Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the isolation board 2 Take off the isolation board gently 3 Use the 5 mm hexagon wrench socket t...

Page 20: ...3 screws used for fastening the SMA cable Disassembly Steps 1 Use the 8mm hexagon wrench socket to remove 3 screw that secure the SMA cable 2 Remove the SMA cable gently Tip Before disconnecting the S...

Page 21: ...ion screw used for fastening the interface board Disassembly Steps 1 Use the T10 screwdriver to remove 4 screws that secure the interface board 2 Take off the interface board gently Tip Before disconn...

Page 22: ...00 R Service Guide Assembly Procedures The assembly procedures are simply the reversal of the disassembly procedures Check whether the cables are correctly connected and whether all the screws are ins...

Page 23: ...you can connect the probe compensation output signal to the faulty channel to locate the problem and then determine whether the channel or the item to be tested has a problem 3 Resample the signal 3 T...

Page 24: ...nue to operate the instrument Besides regular test and calibration should be performed to ensure the accuracy of its performance 4 Arrange the instrument properly after you complete the operation 5 Ke...

Page 25: ...do not expose it to caustic liquids WARNING To avoid short circuit resulting from moisture or personal injuries ensure that the instrument is completely dry before connecting it to the power supply En...

Reviews: