![Rigol DS4000E Series Programming Manual Download Page 63](http://html1.mh-extra.com/html/rigol/ds4000e-series/ds4000e-series_programming-manual_1460996063.webp)
RIGOL
DS4000E Programming Guide
2-51
:CALCulate:LOGic
Command List:
:CALCulate:LOGic:ATHReshold
:CALCulate:LOGic:BTHReshold
Syntax
:CALCulate:LOGic:ATHReshold <thre>
:CALCulate:LOGic:ATHReshold?
:CALCulate:LOGic:BTHReshold <thre>
:CALCulate:LOGic:BTHReshold?
Description
Sets or queries the threshold of Source A or Source B in logic operation.
Parameter
Name
Type
Range
Default
<thre>
Real
(-4 x VerticalScale - Offset) to (4 x VerticalScale - Offset)
Wherein, VerticalScale is the vertical scale of the source
channel, refer to the :CHANnel<n>:SCALe command;
Offset is the vertical position of the source channel, refer
to the :CHANnel<n>:OFFSet command.
0
Return Format
The query returns the threshold level in scientific notation.
:CALCulate:LOGic:INVert
Syntax
:CALCulate:LOGic:INVert <bool>
:CALCulate:LOGic:INVert?
Description
Enables or disables the invert display of the logic operation waveform; or queries the on/off status of the
invert display of the logic operation waveform.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{1|ON}|{0|OFF}}
0|OFF
Remarks
1|ON: turns the waveform invert on. The waveform voltage values are inverted and then displayed.
0|OFF: turns the waveform invert off. The waveform is displayed normally.