RIGOL
DG900 Programming Guide
2-135
[:SOURce[<n>]]:VOLTage:COUPle[:STATe]
Syntax
[:SOURce[<n>]]:VOLTage:COUPle[:STATe] {ON|1|OFF|0}
[:SOURce[<n>]]:VOLTage:COUPle[:STATe]?
Description
Enables or disables the amplitude coupling function.
Queries the on/off status of the amplitude coupling function.
Parameter
Name
Type
Range
Default
[<n>]
Discrete
1|2
1
{ON|1|OFF|0}
Bool
ON|1|OFF|0
OFF
Remarks
After the amplitude coupling function is enabled, CH1 and CH2 take each other as the reference source.
When the amplitude of one channel (this channel is taken as the reference source) is modified, the
amplitude of the other channel is automatically modified accordingly and always keeps the specified
amplitude deviation or ratio with that of the reference channel.
command to set and query the on/off status of
the amplitude coupling function.
Return Format
The query returns ON or OFF.
Example
:SOUR1:VOLT:COUP ON /*Enables the amplitude coupling function.*/
:SOUR1:VOLT:COUP? /*Queries the on/off status of the amplitude coupling function and the query
returns ON.*/
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]
Syntax
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude] {<amplitude>|MINimum|MAXimum}
[:SOURce[<n>]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Description
Sets the waveform amplitude of the specified channel.
Queries the waveform amplitude of the specified channel.
Parameter
Name
Type
Range
Default
[<n>]
Discrete
1|2
1
<amplitude>
Real
Refer to "Remarks".
5 Vpp
Remarks
When [:SOURce[<n>]] or [<n>] is omitted, the system sets the related parameters of CH1 by default.
The minimum of <amplitude> is 2 mVpp and the maximum is limited by the "Impedance"
) and "Frequency/Period"
[:SOURce[<n>]]:FREQuency[:FIXed]
) settings. If the amplitude
value in the command is greater than the corresponding amplitude upper limit or smaller than the
corresponding amplitude lower limit, the waveform amplitude of the specified channel will be set to
the amplitude upper limit or lower limit.
The current amplitude of the instrument is the default value or the one previously set. When the
instrument configuration (e.g. frequency) is changed, if this amplitude is valid, the instrument will still
Summary of Contents for DG952
Page 2: ......
Page 168: ......
Page 181: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 7 ...
Page 185: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 11 ...
Page 187: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 13 ...
Page 199: ...Chapter 4 Programming Examples RIGOL DG900 Programming Guide 4 25 ...
Page 200: ......