![RightAngle Eficiente LT Assembly And Operation Instructions Manual Download Page 8](http://html1.mh-extra.com/html/rightangle/eficiente-lt/eficiente-lt_assembly-and-operation-instructions-manual_1460729008.webp)
Page 8 OF 9
K&A Manufacturing
6703 Zinser Street Schofield, WI 54476
Phone: 800.298.4351
Fax: 866.882.9475
www.raproducts.com
Instruction # 53026
Operation and Reset Procedure:
Plug
the power cord into a standard 110v receptacle. A power surge protector is
recommended. Press the down arrow until the worksurface reaches its lowest
position and the control box clicks several times. The NewHeights workstation is
ready for use.
Reset Procedure: Unplug the power for 30 seconds and plug back in. Hold the down
arrow until the worksurface stops at the bottom and the control box clicks several times.
The workstation is now ready for use.
Troubleshooting:
If you are having any problems with the table operation, contact
RightAngle™ service at 800-298-4351 or [email protected].
Note:
If the leg assemblies are at uneven heights. it is usually caused by an
improperly installed hex rod. Disassemble one of the leg assemblies from the
worksurface and make sure both ends of the hex rod are properly engaged in the hex
drives near the top of the leg assemblies.