User’s manual
Frequency range:
0.1 to 1500 MHz
Frequency entry:
1 kHz resolution
Measurement for
25, 50, 75, 100, 150,
200, 300, 450, and
600-Ohm systems
SWR measurement range:
• 1 to 100 in numerical modes
• 1 to 10 in chart modes
SWR display:
numerical or analog
indicator
R and X range:
• 0…10000, -10000…10000 Ohm
in numerical modes
• 0…1000, -1000…1000 Ohm in chart
modes
Display modes:
• SWR at single or multiple frequencies
• SWR, return loss, R, X, Z, L, C
at single frequency
• SWR chart, 20 to 500 points
• R, X chart, 20 to 500 points
• Smith chart, 20 to 500 points
• Return loss chart, 20 to 500 points
• TDR chart (Time Domain
Reflectometer)
• Cable tools (stub tuner, length
& velocity factor, cable loss
and characteristic impedance
measurement)
Optional open-short-load calibration.
RF output:
• Connector type: N
• Output signal shape: square
• Output power: -10 dBm (at 50 Ohm
load)
Power:
• Three 1.5V alkaline batteries, type AA
• Three 1.2V Ni-MH batteries, type AA
• Max. 4 hours of continuous
measurement, max. 2 days in stand-
by mode when fully charged batteries
are used
• When the analyzer is connected to a
PC or a DC adapter with USB socket, it
takes power from these sources
Interface:
• 320
×
240 color TFT display
• 6x3 keys on the water-proof keypad
• Multilingual menus and help screens
• USB connection to a personal
computer
• Bluetooth Specification v.4.2, LE
Dimensions:
98
×
230
×
53 mm
(3.9
×
9.0
×
2.0 in)
Operating temperature:
0…40 °C
(32…104 °F)
Weight:
442 g (15.6 oz)
Warranty:
2 years
Made in Ukraine.
24
Annex 1
Specifications