RF627, RF627Smart [Revision 2.1.2] 20.09.2021
Laser Scanners
43
Parameter
Factory value
Description
Step counter
– Encoder counter.
Measurement counter
– Internal measurement counter.
22.2. "3D view" section. 3D model display parameters
The parameters of the
3D view
section determine the peculiarities of displaying the
3D model contained in the dump.
Parameters:
Parameter
Factory value
Description
Decimation
No
Decimation of profiles for displaying. Used to reduce the load on
the computer's GPU. If it is necessary to display the entire set of
profiles from the dump (80000), the number of displayed points
reaches 103680000, which significantly slows down the interface.
To eliminate this problem, it is recommended to decimate the
dump when rendering a 3D model.
IMPORTANT:
This parameter does not affect dump export.
Coloring
Heightmap
Profile points coloring mode.
Heightmap
- The color of a point is determined by its height.
Intensity
- Grayscale. The brightness of a point is determined by
the intensity of the radiation reflected from the surface (to use this
mode, it is necessary to enable the transmission of intensity:
General > Stream > Intensity = ON
).
22.3. "Download" section. Downloading profiles
This section is intended for saving profiles in various formats. For more details, go
to par.
"Export of accumulated profiles".
22.4. Operations with profiles
22.4.1. Accumulation of profiles in internal memory of the scanner
To start recording profiles to the scanner's memory, click the button
on the
Dump
indicator. After that, each profile received by the scanner will be saved in its internal
memory. The maximum number of profiles for recording is 80000. Only calibrated profiles
can be recorded (
Data format > Profile
). For the
Raw
format (uncalibrated profile) the
start button will be inactive. During recording, you cannot change the data format and the
Stream
section will not be available.
NOTE:
The accumulation of profiles is carried out in accordance with the selected
Triggering mode (see par.
).