7.4
Discharging the condensate from system with vacuum (Picture 10)
■
Downstream siphon prevents the suction of air from the atmosphere (H
Siphon
).
■
The installation depth (H
Install
) enables the increase of the condensate column, which overcomes the vacuum.
■
The geodesic height (H
Geod
) and siphon height (H
Siphon
) are equal (H
Geod
= H
Siphon
). They depend on the vacuum value and
the required fl ow rate (quantity of condensate).
■
Per meter the pressure increases 0.1 bar because of the geodesic height (H
Geod
).
X
Condensate
Siphon
Air
H
Install
H
Geod
H
Siphon
Condensate
column
Condensate
1064-N
1068-N
Gas + Con-
densate
System with
Vacuum
Picture 10
8
Conformity assessment
The pressure equipment is in accordance with the Pressure Vessel Directive 2014/68/EU, Article 4, subsection 3 and there-
fore bears no CE mark. A detailed declaration of conformity assessment according to PED is available as separate document.
Please request if necessary, if not attached.