15.1 ADR EX Remote Control (Accessories)
When using the additional ADR EX board
of the serial port in the set up of the ADR board
from 2400 or 9600 Baud to I/O O or I/O C
The ADREX-board (order no. ZPK01) allows an external cut off to the ADR controller. It makes sure that all
functions of the controller are OFF or ON. The power supply to the controller remains.
By using an Relay it is possible to extend a alarm signal for an malfunction of the speed controller to a far away
place.
Input and output has to be connected potential free.
Remark: By using the serial port of the ADR it is not possible any longer to connect the ADR to a network with
modem etc.
The ADREX board (ZPK01) is supplied with a short connecting cord to serial port ADR and Plastic mounting
holder. ADREX is compatible to safety regulation IP 22
ADREX for ADR 80 / 230
ADR-EX INPUT (Remote control)
ADR-EX - OUTPUT RELAY - Warning signal
Contact
Function
Setting
I/O O
I/O C
CO Common
CO-NA CO-NC CO-NA CO-NC
I1
Remote control
CO-I1=Open: ADR output: 0%
CO-I1= Closed: ADR in Function
Normal
Open Closed Closed Open
I2
By Pass
CO-I2=Open: ADR in function
CO-I2= Closed: ADR 100% output
Alarm or
malfunction
of ADR
Closed Open Open Closed
15.2 Installation of ZPK01 (ADREX) in ADR 80DP ADR 230DP
Display Message
when
CO- I1 open:
MISSING
EXTERNAL ENABLE
CONFIGURATION
SERIAL PORT: I/O O or
I/O C
Example 1:
ZPK01 installed
on
Example 2:
ZPK01 installed
inside of the box