PASSIVE INFRARED 

DETECTOR 

«

PYRONE-4i

»

 

Installation Guide

Introduction

Passive infrared detector «Pyrone-4i» (hereinafter, the Detector) is 

designed for detection of intrusion into an enclosed secured area and 
generation of alarm signal by opening the output relay contacts.

The Detector is resistant to the ambient light impact and radio 

interference.

The Detector is immune to the interference of small animals (mice, 

rats, birds) provided that the distance to them is not less than 2.5 m.

The Detector can be mounted directly on a ceiling, wall or in a corner 

of a room.

PIR channel ensures wide-angle detection zone and pet immunity to 

animals up to 20 kg with thermal contrast t = 8 °C.

Main Features of the Detector

- Dual-element pyrodetector.
- Spherical lens.
- Microprocessor-based signal processing.
- Mounting height – (2.3 ± 0.1) m.
- Case tamper protection.
- Sensitivity adjustment.
- Digital temperature compensation.

Specifications

Table 1 

Parameter

Value

Maximum detection range

up to 10 m 

Power supply 

8 – 30 V DC, current 12 mA

Relay output contacts

NC 30 mA, 72 V

Alarm signal duration

not less than 2 s

Detection zones

Wide angle, 9 long-range zones, 

5 short-range  zones 

Recommended installation height

2.3 ± 0.1 m

Operating temperature

minus 30 °С ... +50 °С

Permissible air humidity at +25 °С, without 

moisture condensation

95 % 

IP rating

IP41

Dimensions, maximum

90 х 60 х 50 mm

Weight, maximum

60 g

Average service life

8 years

Detection zone layout is shown in Figure 1.

The Detectors in original box may be shipped by any means of 

transportation in covered package (railway, cars, trucks, sealed heated 
compartments of aircraft, ship cargo holds, etc.). 

The Detector is resistant to:

а) transport jolting with the acceleration of 30 m/s

2

 with impact frequency;

from 10 to 120 impacts/s or 15000 impacts with the same acceleration;
b) the ambient temperature  minus 50 … +50 °С;

c) relative air humidity (95 ± 3) % at ambient tempe35 °С.
After transportation under the conditions different to operating conditions 

the Detector shall be ready for work after a maximum of 6 hours.

The average service life of the Detector in standby mode is not less than 

60 000 hours.

Scope of Delivery

Each Detector unit package contains the items listed in Table 2.
Table 2

Item

QTY

Passive infrared detector «Pyrone-4i»
Swivel bracket
Passive infrared detector «Pyrone-4i». Installation Guide

1 pc.
1 pc.

1 copy

LED Indication

Red LED indicator located on the front cover shows the operation status 

of the Detector in accordance with Table 3.

Table 3

Message

LED indication state

«Warm-up time»

Indication is ON till the moment of the Detector readiness 

«Norm»

Indication is OFF

«Alarm»

LED indicator is lighting for 3 s

Choosing  a Place of Installation for the Detector 

The Detector is designed for indoor application.
When choosing the place for installation of the Detector, please note 

that the detection zone may be blocked by non-transparent obstacles 
(curtains, houseplants, cabinets, bookcases, etc.), as well as glass and 
mesh partitions. There must be no windows, air conditioners, space 
heaters or heating radiators in the Detector observation zone.

Alarm loop and power supply wires should be located far enough from 

the power supply cables.

To avoid false alarms install the Detector vertically.

Installation the Detector 

- Push the lock with a screw-driver through the hole on the lower side 

of the Detector base (See Figure 2) and remove the cover.

- In case of the Detector installation without the swivel bracket remove 

the printed circuit board (PCB) by pushing the PCB locating pin.

- Drill the holes in the base for wires insertion and mounting of the 

Detector.

- Choose the place of installation, mark out and drill the holes 

correspondingly in the place of the Detector mounting.

- Insert the wires through the holes in the Detector base, leave several 

centimeters of the mounting wire for connecting to the leading-in socket.

- Connect the wires in accordance with Figure 3.
- Mount the base on the chosen place of installation.
- Place the PCB in the place (if it was removed before).
- Put back the cover.

0

2.3 m

90

о

10 m

10 m

Figure 1 – Detection Zone Layout

The Detector ensures stable operation without activation of false alarms 

triggered by small animals movement, background light  differentials, 
convective air flows, slow temperature changes, power surge in power 
supply circuit, electrostatic discharge, FM-band electromagnetic fields.

The Detector provides no interferences to other comparable detectors, 

detectors of the other type and designation, as well as to any home radio 
equipment.

Figure 2 – Base

Figure 3

-

12V+                      

to PC

Power supply

ALARM

Tamper                      

to PC

For wall 
mounting

Opening for
 the cover latch

Port plug for 
wiring

For 
fastening 
the base to 
the swivel 
bracket

PCB locating 
pin

For corner 
mounting