9 Functional Testing
Detection zone alignment (see Figure 2) should be checked as
follows:
- set jumper IND (LED is ON);
- energize the Detector and wait for 1 minute;
- start walking through the detection zone at a speed rate
0.5 – 1 m/sec. When two zone lines are crossed, the Detector transmits
an alarm message (LED indicator switches ON and the relay contacts
open);
- cross the detection zone on the other side and define it’s other
border. When there is no motion in the detection zone, alarm messages
should not be generated.
In case the detection zone is screened by some objects (curtain
holders, curtains, door trims), then position of the Detector should
be changed.
If additional alignment of the detection zone is needed, you may
use a universal swivel bracket (available optionally).
After retesting install the IND jumper to the required mode position
depending on protection tactics.
10 Self-Test Mode
The Detector provides self-testing automatically. During this mode
input voltage and ambient temperature values are checked.
In temperature range near to 36 °С (human body temperature), the
sensitivity threshold shift takes place, resulting in detectability level
increase.
In case of voltage drop lower than 9
-1
V, «Failure» message is
generated by opening the relay output contacts repeated by periodical
LED indicator blinking during failure and 10 sec after it’s elimination.
ATTENTION!
The Detector must be checked at least annually in
order to test their performance.
11 Storage and Transportation
The Detectors in their original packing may be shipped by any
transport means in covered vehicles (in railway, cars, trucks, sealed
heated compartments of aircraft, ship cargo holds, etc). The storage
room should be free from current-conducting dust, acid vapors, alkali
and gases that cause corrosion and destroy insulation.
The Detectors in their original packing may be stored not more than
3 months. During this period the Detector package should not have
bloodshot spots and impurities.
Upon the expiry of 3 months, the Detector should be released from
the package.
12 Manufacturer’s Guarantees
The Manufacturer guarantees conformity of the Detector to it’s
Technical Specifications if conditions of transportation, storage,
assembling and operation are observed. The guaranteed storage
period is 63 months since the date of manufacturing the Detector.
The guaranteed period of operation is 60 months since the date of
commissioning within the storage period guaranteed.
The Detectors that are found to non-conforming to it’s Technical
Requirements shall be repaired by the Manufacturer, provided the
installation and operation rules have been complied with.
13 Packing Certificate
Passive infrared detector «Foton-SH2» has been manufactured in
compliance with the active technical documentation and classified as
fit for operation and packed by «RIELTA» JSC.
Packing date _______________________________
month, year
«RIELTA» JSC, www.rielta.com,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected].
Made in Russia
Rev. 4, 10 of 13.09.19
v.2