9 Functional Testing

Detection zone alignment (see Figure 2) should be checked as 

follows:

- set jumper IND (LED is ON);
- energize the Detector and wait for 1 minute;
- start walking through the detection zone at a speed rate  

0.5 – 1 m/sec. When two zone lines are crossed, the Detector transmits 
an alarm message (LED indicator switches ON and the relay contacts 
open);

- cross the detection zone on the other side and define it’s other 

border. When there is no motion in the detection zone, alarm messages 
should not be generated.

In case the detection zone is screened by some objects (curtain 

holders, curtains, door trims), then position of the Detector should 
be changed.

If additional alignment of the detection zone is needed, you may 

use a universal swivel bracket (available optionally).

After retesting install the IND jumper to the required mode position 

depending on protection tactics.

10 Self-Test Mode

The Detector provides self-testing automatically. During this mode 

input voltage and ambient temperature values are checked.

In temperature range near to 36 °С (human body temperature), the 

sensitivity threshold shift takes place, resulting in  detectability level 
increase.

In case of voltage drop lower than 9

-1

 V, «Failure» message is 

generated by opening the relay output contacts repeated by periodical 

LED indicator blinking during failure and 10 sec after it’s elimination.

ATTENTION! 

The Detector must be checked at least annually in 

order to test their performance.

11 Storage and Transportation 

The Detectors in their original packing may be shipped by any 

transport means in covered vehicles (in railway, cars, trucks, sealed 
heated compartments of aircraft, ship cargo holds, etc). The storage 
room should be free from current-conducting dust, acid vapors, alkali 
and gases that cause corrosion and destroy insulation. 

The Detectors in their original packing may be stored not more than 

3 months. During this period the Detector package should not have 
bloodshot spots and impurities.

Upon the expiry of 3 months, the Detector should be released from 

the package. 

12 Manufacturer’s Guarantees

The  Manufacturer  guarantees  conformity  of  the  Detector  to  it’s 

Technical Specifications if conditions of transportation, storage, 
assembling and operation are observed. The guaranteed storage 
period is 63 months since the date of manufacturing the Detector.

The guaranteed period of operation is 60 months since the date of 

commissioning within the storage period guaranteed.

The Detectors that are found to non-conforming to it’s Technical 

Requirements shall be repaired by the Manufacturer, provided the 
installation and operation rules have been complied with.

13 Packing Certificate

Passive infrared detector «Foton-SH2» has been manufactured in 

compliance with the active technical documentation and classified as 
fit for operation and packed by «RIELTA» JSC.

Packing date _______________________________ 

month, year

«RIELTA» JSC, www.rielta.com,

Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected].

Made in Russia

Rev. 4, 10 of 13.09.19

v.2

Reviews: