9.3 It is not recommended to install CN-Repeator at the following 

places:

- on massive metal constructions and closer than 1 m to them;
- closer than 1 m to lines of force as well as water or gas pipes;
- near sources of interference;
- inside metal constructions.
9.4 Power supply wires should be located far enough from the 

power cables. Install CN-Repeator in such a position, that antenna 
has vertical orientation. 

10 

Transferring Control over Detectors to CN-Repeator

Transferring control over detectors  to CN-Repeator is fulfilled in 

accordance with a «CN-Contact-R» protocol ver. 6 and higher.

11 Firmware Update 

Update of an internal software is carried out by means of PC with 

«Ladoga-RK» Configurator installed. Before connecting to the PC via 
USB interface unit, disconnect CN-Repeator  external and reserve 
power supply and then install jumper on «Reset» contacts. 

12  Storage and Transportation

12.1 The CN-Repeator in original package may be transported by any 

transport facility in closed vehicles over any distances in compliance 
with the existing shipping rules concerning the respective means of 
transport. 

12.2 The storage room shall be heated and ventilated, as well as 

free from current-conducting dust, acid vapors, alkali and gases that 
cause corrosion and destroy insulation.

13 Manufacturer’s Guarantees

13.1  «RIELTA»

  JSC  guarantees  conformity  of  the  Detector  to  it’s 

Technical Specifications if conditions of transportation, storage, 
assembling and operation are observed. The guaranteed storage period 
is 63 months since the date of manufacturing the Detector. 

13.2 The guaranteed period of operation is 60 months since the date 

of commissioning within the storage period guaranteed.

13.3 For guaranteed maintenance, please contact:
«С.Nord» STCF
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC «Obvodny Dvor» 
Phone: (812) 327-16-36
E-mail: [email protected], [email protected], www.cnord.ru

14 Packing Certificate

Wireless zone extension repeater «CN-Repeator» has been 

manufactured in compliance with the active technical documentation 
and classified as fit for operation and packed by «RIELTA» JSC.

Packing date _______________________________ 

month, year

Rev. 3 of 10.06.2016

№00113

By order of «С.Nord» STCF, www.cnord.ru
Russia, 190020, St. Petersburg,
Obvodny Channel emb., 199-201, build.13, BC «Obvodny Dvor»,
Phone: (812) 327-16-36, [email protected]
Technical support: [email protected], http://support.cnord.ru

Made in Russia  

The Manufacturer: «RIELTA» JSC, www.rielta.com
Russia, 197101, St. Petersburg, Chapaeva str., 17
Phone /fax: +7 (812) 233-03-02, 703-13-60, [email protected]
Technical support: phone +7 (812) 233-29-53, 703-13-57, [email protected]

Reviews: