TECHNICAL DATA
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Sound pressure measured in manufacturers combustion laboratory, with burner operating on test boiler and at maximum rated output.
VARIANTS
ACCESSORIES
(optional):
•
STATUS
(see page 16):
code
3010321
• DEGASSING UNIT
It may occur that a certain amount of air is contained in the light oil sucked up by the pump. This air may originate from the light oil itself as a
consequence of depressurization or air leaking past imperfect seals.
In double-pipe systems, the air returns to the tank from the return pipe; in single-pipe systems, the air remains in circulation causing pressure var-
iations in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the burner in single-pipe installations.
Degassing units are provided in two versions:
CODE
3010054
without filter
CODE
3010055
with filter
Degassing unit characteristics
• Burner delivery
: 80 kg/h max
• Light oil pressure
: 0,7 bar max
• Ambient temperature
: 40 °C max
• Light oil temperature
: 40 °C max
• Attachment connectors
: 1/4 inch
MODEL
RL 28
RL 38
RL 38
RL 50
TYPE
652 T1
653 T1
653 T1
654 T1
OUTPUT
(1)
DELIVERY
(1)
2nd stage
kW
166 - 332
143 - 286
14 - 28
237 - 450
204 - 387
20 - 38
237 - 450
204 - 387
20 - 38
296 - 593
255 - 510
25 - 50
Mcal/h
kg/h
1st stage
kW
95 - 166
118 - 237
118 - 237
148 - 296
127 - 255
12,5 - 25
Mcal/h
82 - 143
102 - 204
102 - 204
kg/h
8 - 14
10 - 20
10 - 20
FUEL
LIGHT OIL
- Net calorific value
kWh/kg
Mcal/kg
11,8
10,2 (10.200 kcal/kg)
- Density
kg/dm
3
0,82 - 0,85
- Viscosity at 20 °C
mm
2
/s max 6 (1,5 °E - 6 cSt)
OPERATION
• Intermittent (min. 1 stop in 24 hours).
• Two-stage (high and low flame) and single-stage (all - nothing).
NOZZLES
number
2
STANDARD APPLICATIONS
Boilers: water, steam, diathermic oil
AMBIENT TEMPERATURE
°C
0 - 40
COMBUSTION AIR TEMPERATURE
°C max
60
ELECTRICAL SUPPLY
V
Hz
230 ~ +/-10%
50 - single-phase
230 - 400
with neutral
~ +/-10%
50 - three-phase
ELECTRIC MOTOR
rpm
W
V
A
2800
300
220 - 240
2,4
2800
420
220 - 240
2,8
2800
450
220/240 - 380/415
2,0 - 1,2
2800
650
220/240 - 380/415
3,0 - 1,7
MOTOR CAPACITOR
µ
F/V
12,5/450
16/450
IGNITION TRASFORMER
V1 - V2
I1 - I2
230 V - 2 x 5 kV
1,9 A - 30 mA
PUMP
delivery (at 20 bar)
pressure range
fuel temperature
kg/h
bar
° C max
45
10 - 18
60
67
4 - 18
60
67
4 - 18
60
88
4 - 18
60
ELECTRICAL POWER CONSUMPTION
W max
370
600
560
750
ELECTRICAL PROTECTION
IP 44
IN CONFORMITY WITH EEC DIRECTIVES
89/336 - 73/23 - 92/42 - 98/37
NOISE LEVELS
(2)
dBA
68,0
70,0
70,0
75,0
Model
Code
Electrical
supply
Blast tube
lenght mm
RL 28
3473232
3473233
single-phase
single-phase
216
351
RL 38
3474132
3474133
3474332
3474333
single-phase
single-phase
three-phase
three-phase
216
351
216
351
RL 50
3474632
3474633
three-phase
three-phase
216
351