3.4
ELECTRICAL WIRING
D4034
ESEGU
ITO IN
FAB
BRICA
WARNING
CONTROL BOX
To remove the control-box from the burner, loosen screw (
A,
fig. 9)
and pull to the arrow direction, after removing all components, the
7 pin plug
and earth wire
.
In case of disassembly of the control box, retighten the screw
(A) with a torque wrench setting of 1 – 1.2 Nm.
DO NOT EXCHANGE NEUTRAL WITH PHASE
7 pin plug
7 pole socket
Black
White
Capacitor
Main switch
T6A
Motor
Safety
thermostat
Blue
Oil valve
Hour counter
(230V - 0.1A max.)
Limit
thermostat
Remote lock-out signal
(230V - 0.5A max.)
Ignition
electrodes
Brown
Burner-earth
CARR
IED-OU
T IN TH
E
FACTORY
553SE/H
CONTROL BOX
Photoresistance
PE
L
N
~
50Hz 230V
Blue
Bro
wn
Blue
TESTING
Check the shut-down of the
burner by opening the thermo-
stats and the lock-out by
dark-
ening
the photoresistance.
NOTES:
– Wires of min. 1 mm
2
section. (Unless requested
otherwise by local standards and legislation).
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
S7217
Fig. 9
A