USER
34
8
Press the OK key to con
fi
rm. The new
end time is displayed.
9
Turn the knob clockwise.
10
Press the OK key. The start time of the
second heating time interval blinks.
11
Continue with step 3 to set the sec-
ond and the third heating time in-
tervals for Monday.
12
Turn the knob clockwise. The heating
program for Tuesday appears.
13
Continue with step 2 and set the
three heating times for each day of
the week. If you have to cancel an
existing heating time, set the start
time and the end time with the knob
to "----".
14
Then turn the selector back to “Run”.
Heating program 2 is now set. To ac-
tivate it, set “ Automatic mode 1”
to operative
.
SWITCH OFF
Turn the knob SELECTION on MODE position,
using the rotary knob, select .
At the end position of the knob back to
RUN SELECTION
SWITCH OFF FOR LONG PERIODS
Turn the knob SELECTION on MODE, using
the rotary knob, select
At the end position of the knob back to
RUN SELECTION
Turn the
Close the fuel cocks and thermal plant
and health.
9
In this case the anti-freezing systems
and antilock are deactivated.
Empty the heating system and health
if there is danger of frost.
9
The Riello Sales Service is available if
the above procedure is not easily im-
plemented.
DISPLAY OF FAULTS
The display of faults is performed with
EXXX, where XXX is the fault code generat-
ed or from the remote control or from the
boiler. This is displayed in place of the
time on the information line of the dis-
play, the signal is
fi
xed if the alarm does
not require RESET whereas it is blinking
if RESET is required, with a triangle on
the right side of the display next to the
wording RESET.
The following table shows the error codes
generated by the timed thermostat.
Fault
No.
Description
E10
No
fl
ame detected
E20
High limit thermostat
E21
over heat under
fl
oor thermostat
/condensate level high
E26
High limit return temperature
probe
E28
Flow / return
T error
E29
Shigh limit fume temperature
probe
E34
Fan error
E40
low water pressure (after 10
minutes)
E41
low water pressure
E52
Internal PCB failure (electronic
generic fault)