background image

Residence Condens i

ISTRUZIONI PER L’UTENTE
USER INSTRUCTIONS

0

4

/2

0

15

co

d

200

9

790

1 r

e

v.

 0

Summary of Contents for Residence Condens i

Page 1: ...Residence Condens i ISTRUZIONI PER L UTENTE USER INSTRUCTIONS 04 2015 cod 20097901 rev 0...

Page 2: ......

Page 3: ...tura Regolamento Delegato UE N 811 2013 Regolamento Delegato UE N 813 2013 Regolamento Delegato UE N 814 2013 solo modello KIS i 0063CQ3187 Garanzia La caldaia Residence Condens i r gode di una garanz...

Page 4: ...atura riscaldamento con sonda esterna collegata 12 Regolazione della temperatura sanitaria 13 Spegnimento temporaneo 14 Spegnimento per lunghi periodi 14 Anomalie e soluzioni Display e codici anomalie...

Page 5: ...di regolazione e di ma nutenzione o usi impropri In caso di fuoriuscite d acqua chiu dere l alimentazione idrica ed av visare con sollecitudine il Servizio Tecnico di Assistenza Riello oppure personal...

Page 6: ...zione di pulizia prima di aver scollegato la caldaia dalla rete di alimen tazione elettrica posizionando l interruttore generale dell im pianto su spento vietato tirare staccare torcere i cavi elettri...

Page 7: ...mento 4 Selettore di funzione 5 Funzione Estate 6 Funzione Spento Sblocco 7 Funzione Inverno 8 Funzione Preriscaldo solo modello KIS i 1 2 3 7 6 4 5 8 Residence Condens KIS i una caldaia murale a cond...

Page 8: ...i ope rare in diverse condizioni CASO A solo riscaldamento La caldaia non fornisce acqua calda sanitaria CASO B solo riscaldamento con collegato un bollitore esterno kit accessorio a richiesta gestito...

Page 9: ...ecnico ad esempio dopo un periodo di assenza prolungata In questi casi dovranno essere effet tuati i controlli e le operazioni se guenti Verificare che i rubinetti del com bustibile e dell acqua dell...

Page 10: ...mbiatore sanitario al fine di ridurre i tempi di attesa durante i pre lievi Ruotando il selettore in questa posi zione possibile attivare o disattivare il preriscaldo P0 non attivo P1 attivo fig 4 in...

Page 11: ...no raggiunte le tempe rature impostate dopo di che si por r in stato di stand by mantenen do comunque visualizzato il valore di temperatura Nel caso si verificassero anomalie di accensione o di funzio...

Page 12: ...legata In caso di presenza della sonda ester na il valore della temperatura di man data viene scelto automaticamente dal sistema che provvede ad adeguare rapidamente la temperatura ambiente in funzion...

Page 13: ...azione torna ad essere quella relativa alla temperatura di mandata o dell acqua sanitaria rile vata dalla sonda Modelli IS i CASO A solo riscaldamento regolazio ne non applicabile CASO B solo riscalda...

Page 14: ...ta dalla sonda di mandata scende sotto i 6 C In questa fase viene genera ta una richiesta di calore con ac censione del bruciatore alla mini ma potenza che viene mantenuta finch la temperatura dell ac...

Page 15: ...E BLOCCO AL21 ANOMALIA TERMOSTATO BASSA TEMPERATURA SICUREZZA POMPA CONDENSA BLOCCO AL26 SOVRA TEMPERATURA RITORNO BLOCCO AL28 ANOMALIA DIFFERENZIALE SONDA RITORNO MANDATA BLOCCO AL29 SONDA FUMI SOVRA...

Page 16: ...Assistenza Tecnica Per anomalie AL41 Verificare il valore di pressione sull i drometro posto sul pannello di co mando se inferiore a 0 5 bar proce dere come di seguito descritto Posizionare il seletto...

Page 17: ...LAZIONE VERIFICA DEL TIRAGGIO E DEL CONDOTTO FUMI PULIZIA BRUCIATORE E VERIFICA EFFICIENZA ACCEN SIONE CONTROLLO FUNZIONAMENTO IDRAULICO ANALISI COMBUSTIONE VERIFICA E LUBRIFICAZIONE COMPONENTI GRUPPO...

Page 18: ...anno con una miscela al 50 di ac qua ed alcool denaturato o con pro dotti specifici Non utilizzare carburanti e o spugne intrise con soluzioni abrasive o detersivi in polvere vietata qualsiasi operazi...

Page 19: ...Delegated Regulation EU No 811 2013 Delegated Regulation EU No 813 2013 Delegated Regulation EU No 814 2013 only KIS i model 0063CQ3187 The Residence Condens i r boil er has a specific warranty that...

Page 20: ...erature with an external probe connected 28 Adjusting the domestic hot water temperature 29 Temporary switch off 30 Switching off for an extended period of time 30 Faults and solutions Display and fau...

Page 21: ...used by installation adjustment or maintenance errors or by improper use In the event of a water leakage shut off the water supply and promptly contact the Riello Technical Assis tance Centre or other...

Page 22: ...g operations before dis connecting the boiler from the electricity supply to do this turn the main system switch to OFF IT is forbidden to pull discon nect or twist the electric cables coming out of t...

Page 23: ...ure of heating system water 4 Mode selector 5 Summer mode 6 Off Reset function 7 Winter mode 8 Pre heating function only KIS i model 1 2 3 7 6 4 5 8 Residence Condens KIS i is a condensing wall hung b...

Page 24: ...e of operating in various conditions MODE A heating only The boiler does not supply domestic hot water MODE B heating only with a thermostatically controlled external storage tank accessory kit availa...

Page 25: ...echnical Assistance Centre for example after a lengthy period of absence In such cases the following checks and operations must be carried out Make sure the fuel and water taps of the heating system a...

Page 26: ...anger hot to reduce standby times when a request is made By turning the selector to this position it is possible to activate or deactivate the pre heating P0 not active P1 ac tive fig 4 in summer and...

Page 27: ...er will continue operating until the set temperatures are reached af ter which it will go into standby in any event maintaining the temperature displayed If there are any firing or operation faults th...

Page 28: ...justing the heating temperature with an external probe connected If there is an external probe the out let temperature value is automatically chosen by the system which quickly adapts the ambient temp...

Page 29: ...e display resumes the outlet temperature or the temperature of the domestic hot water detected by the probe IS i models MODE A heating only adjustment not applicable MODE B heating only external stora...

Page 30: ...he temperature measured by the outlet probe drops below 6 C A heat request is generated in this phase with the ignition of the burner at minimum output which is maintained until the water tem perature...

Page 31: ...CKOUT AL21 LOW TEMPERATURE THERMOSTAT CONDENSATION PUMP SAFETY FAULT LOCKOUT AL26 RETURN LINE OVERTEMPERATURE LOCKOUT AL28 RETURN LINE OUTLET PROBE DIFFERENTIAL FAULT LOCKOUT AL29 FLUE GASES PROBE OVE...

Page 32: ...rvice For AL41 faults Check the value of the pressure on the hydrometer on the control panel if it is less than 0 5 bar proceed as follows Position the mode selector to fill slowly by opening the fill...

Page 33: ...T MENTS CHECKING THE DRAUGHT AND FLUE GASES PIPE CLEANING OF THE BURNER AND CHECKING ITS FIRING CHECKING THE HYDRAULIC OPERATIONS COMBUSTION ANALYSIS CHECKING AND LUBRICATING THE HYDRAULIC UNIT COMPON...

Page 34: ...marks dip the cloth in a mixture of 50 water and methylated spirits or use specific products Do not use fuels and or sponges soaked in abrasive solutions or powder detergents IT is forbidden to carry...

Page 35: ......

Page 36: ...to di tutta la sua produzione le caratteristiche estetiche e dimensionali i dati tecnici gli equipaggiamenti e gli accessori possono essere soggetti a variazione As the manufacturer is constantly impr...

Reviews: