GENERAL INFORMATION

 

GENERAL INFORMATION

1.1 

General Safety Information

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The room where the boiler is installed must be proper-

ly ventilated to ensure a sufficient supply of air for correct 

combustion.

 

9

If you notice any water leaks, disconnect the boiler from the 

mains electricity supply and shut off the water supply.

 

9

The boiler must be serviced at least once a year.

 

9

Periodically check that pressure in the central heating cir-

cuit, when cold, is approximately 1.5 bar and below the 

maximum limit specified for the boiler. If necessary, top up 

through the filling cock or contact the 

R

 Technical Assis-

tance Service or a qualified heating engineer.

 

9

If the boiler is not going to be used for an extended peri-

od of time, perform the operations described later in this 

manual.

 

9

This manual is an integral part of the equipment and there-

fore must be stored carefully and must ALWAYS accompany 

the boiler even if it is sold to another Owner or User or trans-

ferred to another plant. If it is damaged or lost, request an-

other copy from your local Technical Assistance Service 

R

.

1.2 

Precautions

The operation of any appliance that uses fuel, electrical power 

and water demands that a number of fundamental safety pre-

cautions be respected:

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

It is forbidden to use electrical devices or equipment, such 

as switches, appliances, etc. if there is a smell of gas or un-

burnt products. If so:

 

− Ventilate the room, opening doors and windows

 

− Close the fuel shut-off cock.

 

0

Do not touch the boiler while barefoot or wet.

 

0

Never clean or service the boiler without first disconnect-

ing it from the mains electricity supply by turning the mains 

power switch and the control panel switch OFF.

 

0

Do not tamper with or adjust the safety or control devices 

without prior authorisation and instructions from the man-

ufacturer.

 

0

Never pull, disconnect, or twist the electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not obstruct or restrict the vents in the room where the 

boiler is installed. Adequate ventilation is essential for cor-

rect combustion.

 

0

Do not expose the boiler to the elements. It is not designed 

for use outdoors.

 

0

It is prohibited to leave inflammable substances and con-

tainers in the room where the boiler is installed.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

 

0

It is forbidden to operate the boiler without water.

Summary of Contents for INSIEME EVO 32 B/100

Page 1: ...cod 20113830 rev 1 04 2016 INSIEME EVO 32 B 100 32 B 100 S EN USER MANUAL ...

Page 2: ...d efficient functioning of your INSIEME EVO 32 B 100 32 B 100 S boiler Please accept our renewed thanks for your purchase Riello S p A CONFORMITY INSIEME EVO 32 B 100 32 B 100 S boilers conform to the following directives Directive 92 42 EEC on efficiency requirements Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Ecodesign Directive 2009 125 CE for energy rel...

Page 3: ...l Safety Information 4 1 2 Precautions 4 1 3 Description of the appliance 5 1 4 Safety devices 5 1 5 System layout 6 1 6 Control panel 8 2 USE 9 2 1 Putting into service 9 2 1 1 Preliminary operations 9 2 1 2 Start up 9 2 1 3 Ignition failure 10 2 1 4 Resetting the burner and safety thermostat 10 2 2 Temporary shutdown 11 2 3 Preparing for extended periods of disuse 11 2 4 Cleaning and servicing t...

Page 4: ...t ALWAYS accompany the boiler even if it is sold to another Owner or User or trans ferred to another plant If it is damaged or lost request an other copy from your local Technical Assistance Service R 1 2 Precautions The operation of any appliance that uses fuel electrical power and water demands that a number of fundamental safety pre cautions be respected 0 0Do not allow children or infirm perso...

Page 5: ...al heating requests 1 4 Safety devices INSIEME EVO 32 B 100 32 B 100 S boilers incorporate the follow ing safety and control devices A manual reset safety thermostat that forces a safe ty shutdown if boiler temperature exceeds the safety threshold 100 C The sensor used to monitor this tem perature is located on the body of the heat exchanger A minimum temperature thermostat that enables the centra...

Page 6: ... safety valve 8 Boiler drain cock 9 Storage cylinder fill cock 10 Storage cylinder expansion vessel 11 Storage cylinder inspection flange 12 Storage cylinder flange insulation 13 Central heating circuit pump 14 Non return valve 15 Boiler circulator 16 Boiler body 17 Flame inspection window 18 Oil burner 19 Storage cylinder with insulation 20 Storage cylinder sensor socket 21 Storage cylinder safet...

Page 7: ... drain cock 9 Storage cylinder fill cock 10 Storage cylinder expansion vessel 11 Storage cylinder inspection flange 12 Storage cylinder flange insulation 13 Central heating circuit pump 14 Non return valve 15 Boiler circulator 16 Boiler body 17 Flame inspection window 18 Oil burner 19 Storage cylinder with insulation 20 Storage cylinder sensor socket 21 Storage cylinder safety valve 22 Storage cyl...

Page 8: ...ng range 55 82 C 5 Electrical power indicator green Lights to show that the boiler is receiving electrical power 6 Burner lockout indicator red Lights to show that the burner locked out 7 Summer I Winter II selector 8 Storage cylinder temperature gauge Displays the temperature of the domestic hot water in the storage cylinder 9 Manual reset for safety thermostat Allows you to reset the boiler if t...

Page 9: ...rcuit is properly de aerated 20 100 4 40 60 80 3 2 1 0 0 120 2 1 2 Start up Once you have completed all the checks listed above proceed as follows to start up the boiler for the first time Turn the boiler s mains power switch ON Set the room thermostat to the required temperature 20 C or if the system has a timer or timer thermostat make sure that this is switched ON and adjusted to the required t...

Page 10: ... to position I Wait for the burner to complete the entire ignition cycle again up to the ignition of the flame 20 100 4 40 60 80 3 2 1 0 0 120 If boiler temperature becomes too high the manual reset safety thermostat trips 9 9No warning signal is given if the safety thermostat trips but the fact that is has tripped can be seen from the boiler tem perature gauge T 100 C Proceed as follows to reset ...

Page 11: ... 80 3 2 1 0 0 120 Turn the room thermostat to about 10 C or select the frost protection function Turn the storage cylinder thermostat to about the middle of the section with one line 20 40 60 80 100 0 120 2 3 Preparing for extended periods of disuse If the boiler is not going to be used for an extended period of time proceed as follows to prepare it for shut down Open the control panel access door...

Page 12: ...f spot checks Regular maintenance is essential for the safety efficiency and durability of the boiler Servicing is a legal requirement and must be performed at least once a year by a professionally qualified heating engineer 2 5 External cleaning Clean the boiler s casing panels and control panel with a soft cloth damped in soapy water To remove marks from the boiler casing use a cloth damped in a...

Page 13: ...rvice The boiler does not reach its tempera ture setpoint Boiler dirty Contact your local Technical Assistance Service Burner capacity insufficient Contact your local Technical Assistance Service Problem with boiler control thermostat Contact your local Technical Assistance Service The generator triggers a thermal safety block Problem with boiler control thermostat Contact your local Technical Ass...

Page 14: ...cyl inder Contact your local Technical Assistance Service Contact your local Technical Assistance Service Contact your local Technical Assistance Service Contact your local Technical Assistance Service Contact your local Technical Assistance Service The central heating or DHW pump is not working Pump seized Electrical connections Contact your local Technical Assistance Service No heat request from...

Page 15: ...15 ...

Page 16: ...Tel 0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Reviews: