![Riello G5 444T50 Operation Manual Download Page 3](http://html.mh-extra.com/html/riello/g5-444t50/g5-444t50_operation-manual_1459519003.webp)
2381
1
TECHNICAL DATA
■
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 89/392/EEC and Efficiency 92/42/EEC
■
The burner meets protection level of IP 40, EN 60529.
Thermal power – output
28 – 60 kW
–
2.3 – 5 kg/h
Fuel
Light oil 35s, max. viscosity at 20 °C: 6 mm
2
/s
Kerosene 28s
Electrical supply
Single phase,
230 V
± 10%
~
50Hz
Motor
Run current 0.85 A – 2850 rpm – 298 rad/s
Capacitor
4
µ
F
Ignition transformer
Secondary 8 kV – 16 mA
Pump
Maximum pressure 14 bar (203 psi)
Absorbed electrical power
0.16 kW
1
– Return line
2
– Suction line
3
– Gauge connection
4
– Pump pressure regulator
5
– Vacuum gauge connection
6
– Screws fixing air-damper
7
– Hydraulic jack with air-damper
8
– Lock-out lamp and reset button
9
– Flange with insulating gasket
10
– Combustion head adjustment screw
BURNER EQUIPMENT
Quantity
Description
1
1
2
1
1
1
1
Flexible pipe with nipple
Flange with insulating gasket
Screws and nuts for flange
Hinge
Screw of pump by-pass
Grommet
Screw with two nuts for flange
Fig. 1
5
D5553
1
2
3
4
8
6
6
7
9
10