19
NORMAL OPERATION / FLAME DETECTION TIME
The control box has a further function to guarantee the correct burner operation (signal:
GREEN LED
permanently on).
To use this function, wait at least ten seconds from the burner ignition and then press the control box button for a minimum of 3 seconds.
After releasing the button, the GREEN LED starts flashing as shown in the figure below.
The pulses of the LED constitute a signal spaced by approximately 3 seconds.
The number of pulses will measure the probe DETECTION TIME since the opening of gas valves, according to the following table:
ACCESSORIES
(optional):
• RADIO DISTURBANCEPROTECTION KIT
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing to the presence of an
INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres, a protection kit is available as an interface
between the control box and the burner.
•
KIT FOR LPG OPERATION:
The kit allows the RS 64 MZ burner to operate on LPG.
•
GAS TRAINS TO COUPLE WITH THE BURNER, ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter):
see
page 8.
NOTE:
The installer is responsible for the addition of any safety device not foreseen in this manual.
SIGNAL
FLAME DETECTION TIME
This is updated in every burner start-up.
Once read, the burner repeats the start-up cycle by briefly
pressing the control box button.
WARNING
If the result is > 2s, ignition will be retarded.
Check the adjustment of the hydraulic brake of the gas valve,
the air damper and the combustion head adjustment.
1 blink
0.4s
2 blinks
0.8s
6 blinks
2.8s
BURNER
RS 64 MZ
Code
3010386
Output kW
400 - 920
Blast tube lenght mm
250
385
Code
3010434
Code
3010435
• KIT LONG HEAD
Code
3010427
• CLEAN CONTACTS KIT
Code
3010419
• GROUND FAULT INTERRUPTER
Code
3010321
• KIT INTERFACE ADAPTER RMG TO PC
Code
3002719
GREEN LED on
wait at least 10s
Press button
for > 3s
signal
signal