5
GENERAL INFORMATION
1.3
Description of the appliance
The
INSIEME EVO 32 BS/100 LN
boiler produces hot water for cen-
tral heating and also produces domestic hot water in an inte-
grated 95 litre storage cylinder.
It can function at low temperature and is oil fuelled.
The single stage, low NOx, fuel oil burner has a horizontal steel
combustion chamber.
Model
INSIEME EVO 32 BS/100 LN
has a sealed combustion cham-
ber.
The boiler body is thoroughly and effectively insulated with a
layer of high density glass wool.
The
INSIEME EVO 32 BS/100 LN
boiler's control logic incorporates a
total shutdown function to minimise energy consumption:
− In "Summer" mode ("Summer/Winter" selector turned to
Summer position), the burner only starts up to restore
the setpoint temperature of the water in the storage
cylinder. In "Winter" mode ("Summer/Winter" selector
turned to Winter position), the burner starts up either in
response to a request for heat from the heating system
(i.e. when the room thermostat switches the heating on)
or to restore the setpoint temperature of the water in the
storage cylinder (DHW heat requests are prioritised over
central heating requests).
1.4
Safety devices
INSIEME EVO 32 BS/100 LN
boilers incorporate the following safety
and control devices:
−
A manual reset safety thermostat
that forces a safe-
ty shutdown if boiler temperature exceeds the safety
threshold (100°C). The sensor used to monitor this tem-
perature is located on the body of the heat exchanger;
−
A minimum temperature thermostat
that enables the
central heating pump only if boiler temperature exceeds
the minimum permissible (50°C);
−
A maximum temperature thermostat
that shuts down
the burner if boiler temperature reaches or exceeds the
default maximum limit ( 82°C) during the heating of do-
mestic hot water in the storage tank;
−
An electronic burner controller
that monitors the correct
functioning of the selected burner program and sends
a lockout signal to the control panel in the event of an
error.
9
The intervention of a safety device indicates a potentially
dangerous malfunction in the system. Contact the manu-
facturer’s Technical Assistance Service immediately.
9
Safety devices must only be replaced by the manufacturer's
Technical Assistance Service using original spare parts. Refer
to the spare parts catalogue supplied with the boiler.
0
Do not use the boiler if any of its safety devices are faulty.
Always check that the boiler is functioning correctly after repairs
have been made.
1.5
Identification
The products are identified by:
Serial number plate
This is located on the boiler body and specifies the serial
number, model, and main technical specifications.
Mod.
Cod.
N°
Qn(max)
kW
Pn(max)
kW
bar
Pms
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
T067771GE
S
X
%
mg/kWh
NO
Pms= bar T = °C
Qn(min)=
Pn(min)=
T067793GE
Qn(max)=
Pn(max)=
Mod.
Cod.
N°
kW
kW
kW
kW
kW
D= l/min
kW
kW
kW
Pmw= bar T = °C
IP
W
V~Hz
RIELLO S.p.A.
Via Ing.Pilade Riello 7
37045 Legnago (VR) - ITALY
TIPO/TYP/TYP/TYPE/TIPO/TIPO:
COMBUSTIBILE/COMBUSTIBLE/BRENNSTOFF/BRANDSTOF/FUEL/COMBUSTIBLE/COMBUSTÍVEL:
PAESE DI DESTINAZIONE/PAYS DE DESTINATION/BESTIMMUNGSLAND/LAND VON BESTEMMING
COUNTRY OF DESTINATION/PAÍS DE DESTINO/PAÍS DE DESTINO:
Data plate
This lists the technical specifications and performance of the
product.
DHW section
Central heating section
Qn
Rated heat input
Pn
Rated useful heat output
IP
Electric degree of protection
Pmw
Maximum operating pressure, DHW circuit
Pms
Maximum operating pressure, CH circuit
T
Temperature
η
Efficiency
D
Specific flow rate
NOx
NOx class
9
If these plates or any other means of clearly identifying the
product are defaced, removed or lost, proper installation
and servicing may be rendered difficult.