2458
6
3.4
ELECTRICAL WIRING
E9153
4
4
3
1
2
CONTROL BOX (see fig. 8)
To remove the control box from the burner follow of the istruction:
➤
Loosen the screw (1), open the protection (2) and remove all
components.
➤
Remove the coil (3).
➤
Loosen the two screws (4).
➤
Move a little the control box and remove the high voltage leads.
Fig. 8
Capacitor
L
N
~
50Hz - 230V
Limit
Oil valve
D4240
CONTROL BOX
Photoresistance
535SE/LD
thermostat
Safety
thermostat
Motor
Remote lock-out signal
(230V - 0.5A max.)
Main switch
T6A
Blue
White
Black
PE
Ignition
electrodes
TESTING:
Check the shut-down of the burner by opening
the thermostats and the lock-out by darkening
the photoresistance.
Burner-earth
NOTES:
– Wires of min. 1 mm
2
section.
(Unless requested otherwise by local stand-
ards and legislation).
– The electrical wiring carried out by the install-
er must be in compliance with the rules in
force in the Country.
DO NOT EXCHANGE NEUTRAL WITH PHASE
WARNING