E-CITY
45
SOLUTION FOR COMMON PROBLEMS
PROBLEM
SOLUTION
CAUSE
The instrument panel does
not work when the power
supply is activated
The instrument panel ope-
rates correctly, but does not
indicate acceleration when
turned on
The battery does not charge
or has insuffi cient charge
Insuffi cient speed or autonom
Check the ignition key and connection components: repair or re-
place them if necessary.
Check the power pin and outlet; repair or replace them if ne-
cessary.
Check and replace fuse if necessary.
Check the instrument panel and replace if necessary.
Charge.
Go to assistance centre.
Go to assistance centre.
Go to assistance centre.
Connect it correctly.
Attach the cable to the battery correctly.
Go to assistance centre.
Recharge.
Check pressure, possible infl ate until reaching correct pressure.
Proper driving style.
Replace the battery.
Normal situation.
Check that the controller operates correctly.
Ignition key ruined or poor connection.
Poor connection between the power pin and the battery
plug.
Circuit with melted fuse.
Instrument panel malfunction.
Accelerator breakdown.
Improper right or left handlebar operation.
Controller/motor breakdown.
Insuffi cient power
The battery charger is not connected to the lithium battery
correctly.
Loose or disconnected cable.
Battery charger operates incorrectly.
Potencia insufi ciente.
Insuffi cient tyre infl ation pressure.
Repeated braking or surge.
Aged battery or charge level depleted.
Temperature too low.
Controller breakdown.