4.4.3.1 Action Button (IO Devices)
Clicking the
action button offers functions to
manage IO devices.
The dialog can be closed by pressing the ESC key
without saving any changes.
Figure 128: Action Button (IO Devices)
Create IO Device Configuration
Function in the region
IO Device Configurations
to create a new IO Device configuration.
General
ID
Defines the unique ID of the configuration.
Type
Shows the device type of configuration.
Name
Defines the configuration name.
Multicast IP
Defines the multicast IP of the audio stream to be transmitted.
Triggers
Input 1 ... 3
Slider to enable up to three input triggers.
Disabled interfaces
are not shown in
drop-down menus.
Output 1 ... 3
Slider to enable up tp three output triggers.
Audio
Channels
Pair
1 ... 6
Off
Disables the audio channel of the respective port.
In and Out
Enables the input and output audio channel of the respective port.
4-Wire
Enables the 4-Wire of the respective port.
Input
Enables only the input audio channel of the respective port.
Output
Enables only the output audio channel of the respective port.
Add IO Devices
Function in the region
Unassigned / Unconnected IO Devices
that allows adding IO devices.
A single IO device must be selected previously.
Select IO Device Config
Selection of an existing configuration or creation of a new configuration. Creating a new
configuration is identical to the feature
Create IO Device Configuration
.
Assign Hardware
Function in the region
IO Device Configurations
that assigns IO devices to a device configuration.
Select Hardware
to assign
Selection of an IO device that should be assigned to the previously selected
configuration.
Unassign Hardware
Executing this command will remove the assigned IO device from the selected configuration without confirmation.
Remove Config
Allows removing one or more selected configurations. A dialog is opened to confirm the action.
This will remove all associated audio channels, triggers and key bindings.
Locate IO Device
Allows identifying the selected IO device visually. The LEDs on the front side of the respective IO device will start
flashing for about 15 seconds.
Clear Assigned Net
Unconnected and existing IO devices in other network spaces can be made available by this feature.
The respective IO device must be selected previously.
This action requires the "Admin PIN" of the Network Space.
Summary of Contents for Bolero 2.0
Page 1: ...User Manual 03 000HB01EG B10 Bolero 2 0 Next Generation Wireless ...
Page 6: ...Bolero 2 0 User Manual Notes 123 6 4 Index 125 ...
Page 123: ...123 Bolero 2 0 User Manual 6 4 Notes ...
Page 124: ...124 Bolero 2 0 User Manual Notes ...
Page 130: ...www riedel net Riedel Communications GmbH Co KG Uellendahler Str 353 42109 Wuppertal Germany ...