Connection to the power supply:
-
Before plugging in the power supply (CEE plug) should be operated
for safety reasons, the emergency stop button.
Conditions for the operation:
-
A driving of the engine is possible only under the following
conditions:
-
All fuses (internal) must be OK
-
Emergency stop button must be unlocked
-
All 3 phases must be present
Direction Selection and driving of the motors:
On the hand control the direction of the motor of the corresponding drive
switch can be performed by pressing.
Emergency shutdown :
Pressing the emergency stop button, the output of the motor control 3 is
disconnected pole, so that the power supply to the motor is interrupted and
the motor has come to a standstill. To release the emergency stop button, this
has to be unlocked by turning the cap.
Fuses:
There are no fuses inside.
Phase sequence / direction of rotation:
The motor controller is equipped with a CEE phase inverter. The standard
phase sequence results in a clockwise rotation (motors driving on). If your
three-phase connection not give a clockwise rotation, you can change by
turning the contacts L1 / L2 within the phase plug the direction of rotation of
your motor. Use to rotate a Screwdriver.