RIDGID RD906500P Series Operating Manual Download Page 27

21 — English

WARRANTY

Proof of purchase must be presented when requesting 
warranty service.
This product is manufactured by One World Technologies, 
Inc. The trademark is licensed from RIDGID, Inc. All 
warranty communications should be directed to One World 
Technologies, Inc., attn: Generator Technical Service at (toll 
free) 1-866-539-1710.

WHAT IS COVERED UNDER THE 3 YEAR 
LIMITED WARRANTY

This RIDGID

®

 generator is warranted to the original purchaser 

only to be free from defects in material and workmanship 
subject to certain exceptions and limitations stated below, 
for a period of three (3) years after date of purchase.
Warranties for other RIDGID

®

 products may vary.

WHAT IS NOT COVERED

This warranty does not apply to damage from misuse, 
alterations, abuse, normal wear and tear, lack of maintenance, 
accidents, or repairs made or attempted by anyone other 
than an authorized service center for RIDGID

®

 generators.

This warranty does not cover repair if:

 

normal use has exhausted the useful life of the generator 
and wear and tear items (including batteries, fixed and 
removable control panels including corresponding cords 
and plugs, digital displays, tires, outlet plugs and circuit 
breakers, switches, and extension cords if applicable)

 

the customer fails to install, maintain, and operate 
the product in accordance with the instructions and 
recommendations of the company set forth in the 
generator operator’s manual

 

the product is used as rental equipment

 

damage occurs due to freezing, water exposure, rust, 
corrosion, thermal expansion, fire, dropping, or improper 
use.

This warranty does not cover freight or labor charges 
associated with the inspection and testing of generators 
which are found not to be a valid warranty claim. 

Gasoline Engine - Warranty:

 The gasoline engine on this 

generator is separately warranted by the engine manufacturer 
and is serviced through the engine manufacturer’s authorized 
service center network. Ridgid, Inc., and One World 
Technologies, Inc., disclaim any and all express or implied 
warranties with respect to the gasoline engine. 

IMPORTANT: Some components not covered under this 
warranty may still be covered by a separate warranty 
issued by the engine manufacturer. Please see the Engine 
Manufacturer Warranty (if any) supplied with this product 
for further details.

One World Technologies, Inc.

P.O. Box 35, Highway 8

Pickens, SC 29671

RIDGID

®

 GENERATOR

3 YEAR LIMITED WARRANTY 

RIDGID, INC. AND ONE WORLD TECHNOLOGIES, INC.,  
MAKE NO WARRANTIES, REPRESENTATIONS OR 
PROMISES AS TO THE QUALITY OR PERFORMANCE OF 
THIS GENERATOR OTHER THAN THOSE SPECIFICALLY 
STATED IN THIS WARRANTY.

HOW TO OBTAIN SERVICE

To obtain service for this RIDGID

®

 generator you must return 

it, freight prepaid, or take it in to a manufacturer- authorized 
service center for RIDGID

®

 generators. You may obtain the 

location of the authorized service center nearest you by 
calling

 (toll free) 1-866-539-1710

 or by logging on to the 

RIDGID

®

 website at 

www.ridgid.com

. When requesting 

warranty service, you must present the original dated sales 
receipt. The authorized service center will repair any faulty 
workmanship, and either repair or replace any part covered 
under the warranty, at our option, at no charge to you.

ADDITIONAL LIMITATIONS

To the extent permitted by applicable law, all implied 
warranties, including warranties of MERCHANTABILITY or 
FITNESS FOR A PARTICULAR PURPOSE, are disclaimed. Any 
implied warranties, including warranties of merchantability or 
fitness for a particular purpose, that cannot be disclaimed 
under state law are limited to three years from the date of 
purchase. One World Technologies, Inc., and RIDGID

®

Inc., are not responsible for direct, indirect, incidental, or 
consequential damages. Some states do not allow limitations 
on how long an implied warranty lasts and/or do not allow 
the exclusion or limitation of incidental or consequential 
damages, so the above limitations may not apply to you. 
This warranty gives you specific legal rights, and you may 
also have other rights which vary from state to state. 
This warranty applies to product sold in the U.S.A., Canada, 
and Mexico only.
Please consult RIDGID’s website at 

www.ridgid.com

 

or call 

(toll free) 1-866-539-1710

 to locate your nearest 

 manufacturer-authorized  RIDGID

®

 generator service facility 

for warranty and non-warranty service on this RIDGID

®

 

generator.

Summary of Contents for RD906500P Series

Page 1: ...ructions 3 4 Specific Safety Rules 4 Symbols 5 7 Electrical 8 9 Features 10 Assembly 11 12 Operation 13 15 Maintenance 16 19 Troubleshooting 20 Warranty 21 25 Parts Ordering Service Back Page AVERTISS...

Page 2: ...eferenced in the operator s manual Consulter l encart volets afin d examiner toutes les figures mentionn es dans le manuel d utilisation Consulte esta secci n desplegable para ver todas las figuras a...

Page 3: ...eptacles prises 120 V C A GFCI 20 A 120 V de CA GFCI 20 A recept culos J AC circuit breakers disjoncteur de C A disyuntor de circuito de CA K 240 V AC 30 amp receptacle prise 240 V C A 30 A 240 V de C...

Page 4: ...A D E C D 9 3 5 4 2 8 7 6 1 1 Axle bessieu eje 2 Spacer carteur espaciador 3 Wheel roue rueda 4 Washer rondelle arandela 5 Hitch pin goupille de s ret pasador del enganche 6 Lock nut crou de blocage t...

Page 5: ...de d part palanca del anegador B START position position de d marrage posici n de arranque C RUN position position de marche posici n de funcionamiento A C B D D A GenSmart monitoring system syst me...

Page 6: ...gout tap n de drenaje del aceite B C Fig 18 A A Fig 15 Fig 16 A Recoil starter grip manchon en lanceur rappel agarradera del arranque retr ctil Fig 14 A Engine OFF switch interrupteur du moteur interr...

Page 7: ...cto de combustible C Fuel filter filtre carburant filtro de combustible D Retaining clip clip de retenue sujetador de retenci n E Fuel line holder support de conduite de carburant porte de la l nea de...

Page 8: ...he nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code conta...

Page 9: ...Never start or run the engine inside a closed or partially enclosed area Breathing exhaust fumes will kill you Do not start or operate the engine in a confined space building near open windows or in o...

Page 10: ...ch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury Do not allow the generator s gas tank to overflow when filling Fill to 1 in below the top neck of the...

Page 11: ...flammable and explosive Fire or explosion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of ser...

Page 12: ...areas away from open windows or doors Do not expose to rain or use in damp locations Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you...

Page 13: ...ies for laws or regulations relating to fire prevention requirements WARNING AVERTISSEMENT L utilisation de cet quipement peut cr er des tincelles susceptibles d enflammer la v g tation s che Il peut...

Page 14: ...plit Phase 1 8 275 N A 850 1200 1 6 275 600 850 2050 1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 EXTENSION CORD CABLE SIZE Refer to the table b...

Page 15: ...d devices it is important to take care when adding electrical loads to the generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to m...

Page 16: ...ing the engine ENGINE OFF SWITCH The engine switch is used to turn the engine off FUEL TANK The fuel tank has a capacity of 7 gallons FUEL VALVE Fuel flow from the fuel tank to the engine is turned on...

Page 17: ...ith this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury WARNING Do not attempt to operate the generator unt...

Page 18: ...ch pins 2 wheels ASSEMBLY Raise the handle end of the generator high enough to gain access to the frame bottom securely position props underneath to support Insert the axle bolt through the spacer the...

Page 19: ...NOTICE This product is equipped with a spark arrestor that has been evaluated by the USDA Forest Service however product users must comply with Federal State and local fire prevention regulations Chec...

Page 20: ...t the entire fuel system OXYGENATED FUELS NOTICE Do not use E15 or E85 fuel or fuel containing greater than 10 ethanol in this product It is a violation of federal law and will damage the unit and voi...

Page 21: ...3 feet of clearance on all sides of this product including overhead Allow a minimum of 30 minutes of cool down time before storage Heat created by muffler and exhaust gases could be hot enough to caus...

Page 22: ...CHECKING CLEANING AIR FILTER See Figure 17 For proper performance and long life keep air filter clean To remove the air filter cover pull up on the wire latch that holds the cover in place This will...

Page 23: ...y recommend that only qualified service technicians perform this service SPARK ARRESTOR See Figure 20 NOTICE This product is equipped with a spark arrestor that has been evaluated by the USDA Forest S...

Page 24: ...gasoline in suitable container for later use make sure gasoline has been treated with fuel stabilizer according to stabilizer manufacturer s instructions REPLACING FUEL FILTER See Figure 23 Occasional...

Page 25: ...r Change Air Filter2 Check Adjust Spark Plug Replace Spark Plug2 Check Adjust Idle Speed Check Adjust Valve Clearance1 2 Clean Fuel Tank and Filter1 2 Check Fuel Hose Fuel Filter Inspect Replace Check...

Page 26: ...air filter element Clean or replace as needed Drain fuel and carburetor Refuel with fresh gasoline If problem continues contact your nearest authorized service center AC receptacle does not work Circu...

Page 27: ...TANT Some components not covered under this warranty may still be covered by a separate warranty issued by the engine manufacturer Please see the Engine Manufacturer Warranty if any supplied with this...

Page 28: ...be warranted for the warranty period defined in subsection b 2 If any such part fails during the period of warranty coverage it must be repaired or replaced by the manufacturer issuing ONE WORLD TECHN...

Page 29: ...rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4 Dirt or grit r...

Page 30: ...l to be identical in all material respects to the part as described in the engine manufacturer s application for certification YOUR WARRANTY RIGHTS AND OBLIGATIONS The United States Environmental Prot...

Page 31: ...at a JD Authorized Warranty Service Facility 5 When the engine is inspected by a JD Authorized Warranty Service Facility the owner shall not be held responsible for diagnostic costs if the repair is d...

Page 32: ...ccorder la borne du fil de terre entre la rondelle frein et l crou puis serrer fermement l crou Raccorder et immobiliser fermement l autre extr mit du fil une source de terre en contact avec le sol un...

Page 33: ...la g n ratrice de la source d alimentation de l appareiletdoitr pondre touteslesloisetcodesdel lectricit applicables Ne pas laisser des enfants ou personnes n ayant pas re u une formation ad quate uti...

Page 34: ...ssage Remplir le r servoir jusqu 25 4 mm 1 po de l ouverture du goulot du r servoir pour permettre l expansion du carburant Ne pas recouvrir le bouchon du r servoir de carburant lorsque le moteur fonc...

Page 35: ...tr mement inflammables et explosifs Un incendie ou une explosion peut entra ner des br lures graves voire la mort Surface chaude Pour viter les risques de blessures ou de dommages viter tout contact a...

Page 36: ...EXT RIEUR et loin des fen tres des portes et des vents AVERTISSEMENT CONCERNANT LES SURFACES BR LANTES Ne pas toucher le silencieux ou le cylindre en aluminium du moteur Ils sont BR LANTS et peuvent...

Page 37: ...incendie pour conna tre toutes les lois et tous les r glements portant sur les exigences en mati re de pr vention des incendies 940947003 03 ADVERTENCIA El uso de este equipo puede producir chispas p...

Page 38: ...des cordons prolongateurs utilis s est capable de porter la charge requise Des tailles de c bles inad quates peuvent causer une chute de tension qui peut endommager l appareil et surchauffer le cordon...

Page 39: ...L NERGIE Pour prolonger la dur e de vie du g n ratrice et des appareils reli s il est important d effectuer l ajout de charges lectriques suppl mentaires au g n ratrice avec soin Rien ne doit tre con...

Page 40: ...r Il est aussi utilis pour arr t le moteur R SERVOIR DE CARBURANT Le r servoir de carburant a une contenance de 26 5 l 7 gallons ROBINET DE CARBURANT Le d bit de carburant du r servoir de carburant ve...

Page 41: ...t De telles alt rations ou modifications sont consid r es comme un usage abusif et peuvent cr er des conditions dangereuses pouvant entra ner des blessures graves AVERTISSEMENT Ne pas tenter d utilise...

Page 42: ...ever l extr mit du g n ratrice l oppos du poign e rappel suffisamment pour acc der au bas du cadre placer des cales en dessous pour obtenir un bon support Ins rer un boulon de travers un carteur puis...

Page 43: ...ser la g n ratrice AVERTISSEMENT La familiarit avec l appareil ne doit pas faire oublier la vigilance Ne pas oublier qu une fraction de seconde d inattention peut entra ner des blessures graves AVERTI...

Page 44: ...teur de carburant et le carburant avant de remplir le r servoir en utilisant un contenant carburant ou tout autre r cipient pour carburant approuv et agiter l g rement pour bien m langer NOTE Pourma t...

Page 45: ...position On Marche carter gauche le levier d tranglement la position START D MARRAGE NOTE Si le moteur est chaud ou que la temp rature est sup rieure 10 C 50 F carter droit le levier d tranglement su...

Page 46: ...a salet et les d bris Nettoyer les vents pression basse ne d passant pas 25 psi Essuyer les surfaces ext rieures du g n ratrice avec un chiffon humide INSPECTION NETTOYAGE DU FILTRE AIR Voir la figure...

Page 47: ...8 mm 0 028 0 031 po Pour augmenter l cartement si n cessaire courber avec pr caution l lectrodedeterre sup rieure Pourr duirel cartement ENTRETIEN taperdoucementl lectrodedeterresurunesurfacedure Ins...

Page 48: ...oi il est n cessaire de le remplacer Pour se procurer un filtre essence de remplacement veuillez communiquer avec le service la client le de RIDGID au num ro suivant 1 866 539 1710 Pour remplacer Tour...

Page 49: ...n autre manuel du moteur est fourni avec cette g n ratrice veuillez respecter le calendrier d entretien pr sent dans le manuel du moteur au lieu de suivre les instructions d entretien d crites ci dess...

Page 50: ...fait avec un mauvais carburant V rifier le l ment du filtre air Nettoyer ou remplacer selon le besoin Vidanger le carburant et le carburateur Remplir d essence fra che Si le probl me continue contact...

Page 51: ...ld Technologies Inc en d mentez et toutes les garanties explicites ou implicites pour ce moteur essence RIDGID G N RATRICE GARANTIE LIMIT E DE SERVICE DE 3 ANS IMPORTANT Certains composants n tant pas...

Page 52: ...faillance durant la p riode de garantie elle doit tre r par e ou remplac e par le fabricant offrant la garantie Une telle pi ce r par e ou remplac e dans le cadre de la garantie doit tre garantie pour...

Page 53: ...burateur des soupapes gomm es ou de la corrosion et de la rouille sur les pi ces de moteur 3 R paration requise suite la surchauffe La plupart du temps suite un volant ventilateur passages d air d adm...

Page 54: ...ment toutes les r glementations applicables adopt es par l Environmental Protection Agency EPA conform ment son pouvoir respectif et est VOS DROITS ET RESPONSABILIT S EN VERTU DE CETTE GARANTIE La Un...

Page 55: ...antipollution 4 La r paration ou le remplacement de toutes les pi ces li es aux missions et couvertes par la garantie du syst me antipollution doivent tre effectu s sans frais par un centre de servic...

Page 56: ...a un ngulo de a lo sumo 45 Si aun as la jabalina se encuentra con el estrato rocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo superior...

Page 57: ...strucci n para su manejo Nunca arranque ni accione el motor dentro de un rea total o parcialmente cerrada La inhalaci n de las emanaciones del escape puede ser mortal No haga arrancar o funcionar el m...

Page 58: ...a pendiente no mayor de 4 Utilicelaunidadalairelibreenun reabienventiladaeiluminada aislada de las reas de trabajo para evitar la interferencia del ruido Si se utiliza el generador en condiciones h me...

Page 59: ...vapores del mismo son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corpor...

Page 60: ...RTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POCOS...

Page 61: ...r doit communiquer avec le service local d incendie pour conna tre toutes les lois et tous les r glements portant sur les exigences en mati re de pr vention des incendies 940947003 03 ADVERTENCIA El u...

Page 62: ...EAJUSTE CARGAS DE MOTORES EL CTRICOS Es caracter stico en el funcionamiento normal de los motores el ctricos comunes consumir durante el arranque hasta seis veces su corriente de operaci n Esta tabla...

Page 63: ...ma en vatios 2300 Potencia total arranque en vatios requerida 6860 ADMINISTRACI N DE LA POTENCIA A fin de prolongar la vida til del generador y los dispositivos acoplados es importante tener cuidado a...

Page 64: ...em s se utiliza para apagar del motor TANQUE DE COMBUSTIBLE El tanque de combustible tiene una capacidad de 26 5 L 7 galones V LVULA DE COMBUSTIBLE El flujo de combustible del tanque de combustible al...

Page 65: ...n o modificaci n constituye maltrato y puede causar una condici n peligrosa y como consecuencia posibles lesiones corporales graves ADVERTENCIA No intente accionar el generador antes de terminar de ar...

Page 66: ...as ARMADO Levante el extremo del mango del generador de modo que pueda acceder a la parte inferior del bastidor Coloque los soportes firmemente por debajo para que sirvan de apoyo Inserte un perno a t...

Page 67: ...Departamento de Agricultura de EE UU sin embargo los usuarios del producto deben cumplir con los reglamentos de prevenci n de incendios locales estatales y federales Consulte a las autoridades que co...

Page 68: ...regarlo directamente al tanque de combustible del generador Coloque de nuevo la tapa del tanque de combustible y aseg rela Arranque el motor y d jelo funcionar por lo menos cinco minutos para permitir...

Page 69: ...de la agarradera del arranque retr ctil hasta que funcione el motor 6 veces como m ximo NOTA Nopermitaqueelmangoseretraigaviolentamente despu s de arrancar regr selo suavemente a su lugar original Pe...

Page 70: ...as que acortan la vida de servicio del generador Para limpiar la unidad Con un cepillo de cerdas suaves y o una aspiradora afloje y elimine la tierra y la basura Limpie las aberturas de ventilaci n co...

Page 71: ...impie toda la tierra presente alrededor de la base de la buj a Retire los buj as con la llave no incluido MANTENIMIENTO Inspeccione la buj a para ver si est da ada y l mpiela con un cepillo de alambre...

Page 72: ...llodedrenaje delcarburadorpararecibirelcombustible aflojeeltornillo Permita que se drene completamente el combustible y caiga en el recipiente Vuelva a apretar el tornillo de drenaje NOTA Consulte las...

Page 73: ...enimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento...

Page 74: ...de mala calidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combustible y el carburador Reabastezcadegasolinafrescalaunidad Si el problema contin a comun qu...

Page 75: ...pecto al motor de gasolina RIDGID GENERADOR GARANT A DE LIMITADA DE 3 A OS IMPORTANTE A los componentes que esta garant a no cubra los podr cubrir una garant a adicional emitida por el que fabricante...

Page 76: ...to en las instrucciones por escrito debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Si cualquier de dichas partes fallan durante el tiempo de la cobertura de la garant a d...

Page 77: ...antes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados o faltantes 4 El desgaste relacionado con la suciedad o mugre causado por el manteni...

Page 78: ...a EPA conforme con sus respectivas autoridades y b no presentan defectos en material ni mano de obra que en alg n momento durante el per odo de la DERECHOS Y OBLIGACIONES DEL CONSUMIDOR SEG N LA GARAN...

Page 79: ...n el sistema de control de emisiones bajo esta Garant a del ECS ser efectuada sin cargo para el propietario en un Centro de Servicio T cnico de Garant a Autorizado de JD 5 Cuando el motor sea inspecci...

Page 80: ...26 Espa ol NOTES NOTAS...

Page 81: ...27 Espa ol NOTES NOTAS...

Page 82: ...le centre de r parations RIDGID agr le plus proche Veiller fournir toutes les informations pertinentes lors de tout appel t l phonique ou visite Pour obtenir l adresse du centre de r parations agr le...

Reviews: