9 — English
ELECTRICAL
POWER MANAGEMENT
To prolong the life of the generator and attached devices,
it is important to take care when adding electrical loads to
the generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the engine
as described later in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider surge loads in generator capacity
as previously described.
CAUTION:
Do not overload the generator’s capacity. Exceeding
the generator’s wattage/amperage capacity can
damage the generator and/or electrical devices
connected to it.
Tool or Appliance
Estimated*
Running
Watts
Estimated*
Additional
Starting Watts
DIY/Job Site
Quartz Work Light (1000 Watt)
1000
0
Circular Saw (Heavy Duty, 7
1/4”)
1400
2300
Drill (1/2 inch, 5.4 amps)
600
900
Miter Saw (10”)
1800
1800
Battery Charger (15 amp)
380
0
Reciprocating Saw
960
960
Air Compressor (1 HP)
1600
4500
Demolition hammer
1260
1260
Airless Sprayer (1/3 hp)
600
1200
Radio
200
0
Fan (20” Box Fan)
60
200
*Wattages listed are approximate. Check tool or equipment for actual wattage.
Summary of Contents for RD903600 Series
Page 59: ...15 NOTES NOTAS ...