RIDGID PFMR65100 Operator'S Manual Download Page 11

 

RP 380 Press Tool 

 

Ridge Tool Company 

10 

 

 

Daily before use, inspect your press tool and correct any problems to reduce the risk of serious injury from electric shock, 
crushing injures, attachment failure and other causes, and prevent tool damage. 

1.

 

Remove battery from tool. 

2.

 

Clean any oil, grease or dirt from the equipment, especially the handles and controls. This aids inspection  and helps to 
prevent the tool or controls from slipping from your grip. 

3.

 

Inspect the press tool for: 

 

Proper assembly, maintenance and completeness. 

 

Any broken, worn, missing, misaligned or binding parts.  Confirm fabric loops are in good condition. 

 

Confirm attachment mounting pin moves smoothly between the fully open and fully closed position and locks into 
each. Confirm that the run switch moves freely and does not bind or stick. 

 

Presence and readability of warning label. See figure 2. 

 

Any other condition which may prevent safe and normal operation. 

Do not use the press tool until any problems have been repaired. 

4.

 

Inspect  and  maintain  tool  attachments  per  their  instructions.  Remove  attachment  from  the  tool.  Confirm  that 
attachments are in good condition and clearly marked as to use.  

5.

 

Inspect and maintain any other equipment being used per its instructions to make sure it is functioning properly.  

 

Setup and Operation Instructions 

 WARNING 

 

 

 

Keep your fingers and hands away from the tool attachment during the press cycle. 

Your fingers or hands can be crushed, 

fractured or amputated in the attachment or tool or between the attachment, work piece and other objects.

 

Large forces are generated during product use that can break or throw parts and cause injury. 

Stand clear during use and 

wear appropriate protective equipment, including eye protection. 

Use  proper  tool,  attachment  and  fitting  combinations.

  Improper  combinations  can  result  in  an  incomplete  joint,  which 

increase the risk of leaks, equipment damage and injury. 

Follow  setup  and  operation instructions  to reduce  the  risk  of  injury  from crushing  and  other causes  and  to prevent  tool 
damage. 

1.

 

Confirm  have  appropriate  work  area  (See  General  Power  Tool  Safety  Warnings).    Operate  in  clear,  level,  stable,  dry 
location. Do not use tool while standing in water. 

2.

 

Inspect work to be done and determine correct RIDGID tool and attachment for the application per their specifications. 
Using incorrect equipment for an application can cause injury, damage the tool and make incomplete connections. 

3.

 

Confirm all equipment has been inspected and set up as directed in their instructions.  

Removing/Installing Attachment 

1.

 

Remove battery from tool.  

2.

 

Rotate attachment mounting pin 180° to unlock and fully open (Figure 6).  Remove attachment. 

3.

 

If needed, Change Tool Configuration for the attachment (Long / Standard). 

Summary of Contents for PFMR65100

Page 1: ...PRESS CONNECTION TOOLS RP 380 PRESS TOOL SKU PFMR65100 1 2 4 5 6 3 7...

Page 2: ...RP 380 Manual RP 380 Press Tool Operator Manual...

Page 3: ...hanging Tool Configuration Long Standard 11 Preparing Connection 12 Pressing A Fitting With Typical Scissor Jaws 12 Pressing A Fitting With Typical Actuator And Press Ring Set 13 Inspecting The Presse...

Page 4: ...dicates the risk of hands fingers or other body parts being crushed This symbol indicates the risk the electrical shock General Power Tool Safety Warnings WARNING Read all safety warnings and instruct...

Page 5: ...way from moving parts Loose clothes jewelry or long hair can be caught in moving parts If devices are provided for the connection of dust extraction and collection facilities ensure these are connecte...

Page 6: ...ure range specified in the instructions Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire Service Have your power tool serviced by...

Page 7: ...ool Technical Service Department at rtctechservices emerson com or in the U S and Canada call 800 519 3456 Description The RIDGID RP 380 Press Tool when used with appropriate attachments is designed t...

Page 8: ...F switch and Tool Status Lights Need New Figure 3 Machine Serial Number The first 4 digits indicate the year and month of the manufacture 17 year 05 month Run Switch Housing Pressure Release Button At...

Page 9: ...utton Allows tool to be released without completing press If used press connection is not complete and must be repeated Attachment Mounting Pin Holds attachment to tool See figure 6 Sleeve Long Series...

Page 10: ...rating Temperature 15 F to 122 F 10 C to 50 C Weight no battery attachment 2 2 lbs 4 9 Kg Dimensions 20 1 3 35 12 6 510 x 85 x 320 mm Klauke is registered trademark of Gustav Klauke GMBH Korea Dasung...

Page 11: ...oning properly Setup and Operation Instructions WARNING Keep your fingers and hands away from the tool attachment during the press cycle Your fingers or hands can be crushed fractured or amputated in...

Page 12: ...ion Long Standard The RIDGID RP 380 Press Tool can be configured for use with RIDGID Standard or Long Series attachments See Specifications for more information To convert between configurations 1 Rem...

Page 13: ...nd the fitting manufacturers specific installation instructions to reduce the risk of improper press connections and extensive property damage 1 Prepare the connection according to the fitting manufac...

Page 14: ...malfunctions during operation use this procedure In case of emergency release run switch and depress pressure release button 4 Release the run switch 5 Squeeze jaw arms to open jaws 6 Remove jaw from...

Page 15: ...ergency release run switch and depress release button Figure 11 Installing Press Ring onto Fitting Need Pictures Figure 12 Attaching Actuator to Press Ring Need Pictures 4 Release the run switch 5 Squ...

Page 16: ...tery not properly inserted into handle of tool Check to assure battery is fully inserted Attachment is locked onto fitting Press was not successfully completed Push pressure release button to remove j...

Page 17: ...hments Ridge Tool Company provides Standard series press attachments designed specifically for use with RIDGID Standard Press Tools Only use attachments that are specifically designed to press the fit...

Page 18: ...rostatic discharges are present and without causing electromagnet interference to other equipment NOTICE These tools conform to all applicable EMC standards However the possibility of it causing inter...

Reviews: