Summary of Contents for AF3000

Page 1: ...2 1 56 0 18 RU RXU 6DIHW 5HDG DOO LQVWUXFWLRQV FDUHIXOO VVHPEO 2SHUDWLRQ 5HSDLU 3DUWV 48 67 216 25 200 176 5 Part No SP6154 Printed in Canada 5 251 75 7 21 6 67 0 ...

Page 2: ...rborne Filtration System use only RIDGID recommended accessories Sparks inside the motor can ignite flam mable vapors or dust To avoid fire or explosion Do not use this Airborne Filtration Sys tem near flammable or combustible liq uids gases or explosive dusts such as gasoline or other fuels lighter fluid cleaners oil based paints natural gas hydrogen coal dust magnesium dust grain dust or gun pow...

Page 3: ... dam age Always wear safety goggles not glasses complying with ANSI Z87 1 or in Canada CSA Z94 3 M88 shown on pack age Everyday eyeglasses have only impact resistant lenses They are not safety glasses Safety Goggles are avail able at many local retail stores Glasses or goggles not in compliance with ANSI or CSA could seriously hurt you when they break To avoid hearing damage wear ear pro tectors w...

Page 4: ...wing D S Hook 4 E Screw Hook 4 F 3 16 24 Eye Bolt 4 G Extension Spring 4 H Double Loop Chain 4 J 3 16 Lockwasher 8 K 3 16 24 Hex Nut 8 Unpacking and Checking Carton Contents Remove entire contents of carton Check each item against the Carton Contents List Contact 1 800 4 RIDGID if any parts are damaged or missing C A D E F G H J K B ...

Page 5: ...nd when selecting a location 2 Joists are normally sixteen inches apart Spacing of holes on width of unit is 19 7 16 and on length of unit is 26 on center as shown Chain allows for suspension from joist in either direction 3 Unit weighs 40 pounds so suspension should be from center of ceiling joists only WARNING To reduce the risk of injury from a falling unit install in structure that will suppor...

Page 6: ...d out of the unit 10 The exhaust filter slides out of the channel in the cabinet 11 Install a hex nut on an eye bolt until 1 4 of thread is showing below the eye Slip on a lockwasher and put eye bolt in hole in top of cabinet Repeat for other three eye bolts 12 Slip lockwasher and hex nut on eye bolt as shown Repeat for other three eye bolts and then tighten nuts with two wrenches until all nuts a...

Page 7: ... use in rain or where floor is wet This tool is intended for indoor resi dential use only WARNING Do not permit fingers to touch the terminals of plug when installing or removing the plug to or from the outlet If power cord is worn or cut or damaged in any way have it replaced immediately 110 120 Volt 60 Hz Tool Information NOTE The plug supplied on your tool may not fit into the outlet you are pl...

Page 8: ...m pletely understood or if you are in doubt as to whether the tool is properly grounded check with a qualified electri cian or service personnel WARNING If not properly grounded this tool can cause an electrical shock particularly when used in damp locations in proximity to plumbing or out of doors NOTE The adapter illustrated is for use only if you already have a properly grounded 2 prong outlet ...

Page 9: ...uce the risk of fire or electrical shock do not use this Airborne Filtration System with any solid state speed control device Maintenance IMPORTANT To assure product safety and reliability repairs and adjustments should only be performed by Authorized Service Centers always using RIDGID replacement parts Filter Maintenance WARNING To avoid injury from acci dentally starting unplug power cord befor...

Page 10: ...lter for cleaning or replacement review the sec tion in your manual under Installation Procedure following steps 7 8 9 and 10 WARNING For your own safety use only RIDGID replacement filters WARNING To avoid electrical shock be sure to replace screw that secures Fine Filter CAUTION For proper operation make sure Air Flow arrows on the filters are facing the proper direction Air Direction 1 Pre Filt...

Page 11: ...11 Wiring Diagram Black White Wire Nut Black Quick Connections Black Black Black Wire Nut White Ground Blower Switch Light ...

Page 12: ...826424 824311 1 826375 169123 9 824288 824292 824290 825955 816345 1 824300 826041 824597 1 825941 4 825941 5 826152 SP6154 Cabinet Cover Pre Filter Intake Fine Filter Mid Bag Type Filter Exhaust Blower Assembly Cord Assembly Strain Relief Light Switch Assembly Wire Connector Clip Wire Nut Self Ret 8 Hex Nut Flange1 4 20 Gasket 1 8 Max Th x 1 4 x 9 S Hook 1 1 2 Screw Hook 1 9 16 Eye Bolt 3 16 24 x...

Page 13: ...13 Repair Parts Airborne Filtration System Model Number AF30000 1 2 3 4 5 6 7 8 9 10 11 27 14 15 16 17 18 19 20 21 22 23 11 25 24 29 26 13 25 25 28 12 ...

Page 14: ...y warranty on behalf of RIDGID Air Filtration Emerson Electric Co Warranted products will be repaired or replaced at our option at no charge to you and returned to you via prepaid transportation Such replacement or repair is the exclusive remedy available from RIDGID Air Filtration Emerson Electric Co Emerson Electric Co is not liable for damage of any sort including incidental and consequential d...