Detachable Blower Intake

After using the detachable blower of your
Wet/Dry Vac, examine the bottom of the
blower for dust and debris. Check to see
if the intake to the blower has debris
stuck to the plastic vents and foam pad.

To clean the foam pad under the intake
shield of the detachable blower:

1. Remove the three screws holding the

intake shield.

2. Lift the intake shield off and set aside.

3. Lift the foam pad away from the

detachable blower.

4. Remove the foam pad and clean in

warm soapy water or brush debris
away. Allow foam pad to dry.

5. Examine foam pad for reuse. If you

need to replace it, check the service
part section of this manual.

WARNING: To reduce the risk of

injury from accidental starting,
unplug power cord before changing
or cleaning filter or foam pad.

Foam Pad

Intake 
Shield

Screws (3)

6. Replace foam pad by reversing steps

1 thru 4.

7. Reinstall intake shield and 3 screws.

The unit is ready for use.

!

SP6953 Ridgid 1620RV0_SP6542.qxd  1/16/15  10:00 AM  Page 13

Summary of Contents for 1620RV

Page 1: ...R FUTURE REFERENCE WARNING To reduce the risk of injury the user must read and understand the owner s manual before using this product SP6953 Ridgid 1620RV0_SP6542 qxd 1 16 15 10 00 AM Page 1 99 Washi...

Page 2: ...ing such as cigarettes matches or hot ashes Do not vacuum drywall dust cold fireplace ash or other fine dusts with standard filter These may pass through the filter and be exhausted back into the air...

Page 3: ...nings Do not vacuum with any ventilation openings blocked keep free of dust lint hair or anything that may reduce air flow Keep hair loose clothing fingers and all parts of body away from openings and...

Page 4: ...cific usage of your new Vac Unpacking and Checking Carton Contents Key Description Qty A Wet Dry Vac 1 B Accessory Storage Holder 1 C Extension Wands 2 D Qwik Lock Filter 1 E Pro Hose 1 F Caster Feet...

Page 5: ...ighten screws until just snug Do not over tighten as this may tend to deform the caster feet 3 Insert the caster stem into each of the caster feet as shown 4 Push on the caster until the ball on the c...

Page 6: ...receptacles until fully seated with holder clips locked Accessory Storage Holder Removing Accessory Storage Holder Push in both accessory storage holder clips and then pull straight up on rods of acc...

Page 7: ...m Latch Drum Catch Inlet Drain Cap Dust Drum Assembly 1 Locate the lid assembly and the drum assembly assembled earlier 2 Position the lid assembly with the detachable blower handle of the unit locate...

Page 8: ...is now latched to the lid assembly 4 Your new Wet Dry Vac is ready for use With the Wet Dry Vac completely assembled and ready for use insert the push button end of the Pro Hose into the inlet of the...

Page 9: ...e unit on by sliding the switch from position O to position l OFF ON WARNING To reduce the risk of fire explosion or damage to Vac Do not leave Vac running while unattended you may fail to notice impo...

Page 10: ...power cord and empty the drum 4 After using the Vac to pick up liquids the filter must be dried to avoid possible mildew and damage to the filter IMPORTANT To reduce the risk of damage to the Vac do n...

Page 11: ...f injury to bystanders keep them clear of blowing debris Detachable Blower Handle Detachable Blower Latch Detachable Blower Molded Leads Blowing Feature Your Wet Dry Vac has a detachable blower It has...

Page 12: ...t is ready for blowing applications 12 Operation continued Using the Detachable Blower for Blowing Two suggested methods of using the blower are 1 Insert the round end of the blower wand into the blow...

Page 13: ...and set aside 3 Lift the foam pad away from the detachable blower 4 Remove the foam pad and clean in warm soapy water or brush debris away Allow foam pad to dry 5 Examine foam pad for reuse If you nee...

Page 14: ...age to the blower wheel and motor always reinstall the filter before using the Vac for dry material pickup Filter Removal and Installation of the Qwik Lock Filter Filter Removal 1 Hold the filter tabs...

Page 15: ...y Vac looking its best clean the outside with a cloth dampened with warm water and mild soap To clean the drum 1 Dump debris out 2 Wash drum thoroughly with warm water and mild soap 3 Wipe out with dr...

Page 16: ...Vac so they can be readily available The Vac should be stored indoors Casters If your casters are noisy you may put a drop of oil on the roller shaft to make them quieter WARNING To assure product SAF...

Page 17: ...0RV0 WARNING SERVICING OF DOUBLE INSULATED WET DRY VAC In a double insulated Wet Dry Vac two systems of insulation are provided instead of grounding No grounding means is provided on a double insulate...

Page 18: ...rts continued 16 Gallon Professional Wet Dry Blower Vac Model Number 1620RV0 9 5 4 3 2 1 11 17 10 18 19 20 21 22 23 26 27 24 7 8 6 12 25 13 14 15 16 24 SP6953 Ridgid 1620RV0_SP6542 qxd 1 16 15 10 01 A...

Reviews: