background image

Machine Storage

The drain cleaner and cables must be

kept indoors or well covered in rainy weather. Store the
machine in a locked area that is out of reach of children
and people unfamiliar with drain cleaners. This machine
can cause serious injury in the hands of untrained users.

Service and Repair

WARNING

Improper service or repair can make machine un-
safe to operate.

The “Maintenance Instructions” will take care of most of
the service needs of this machine. Any problems not ad-
dressed by this section should only be handled by an au-
thorized RIDGID service technician.

Tool should be taken to a RIDGID Independent Author -
ized Service Center or returned to the factory. 

For information on your nearest RIDGID Independent
Service Center or any service or repair questions: 

• Contact your local RIDGID distributor. 

14

K-45 Drain Cleaning Machine

Accessories

WARNING

The following RIDGID products have been designed
to function with the K-45 Drain Cleaning Machine.
Other accessories suitable for use with other tools
may become hazardous when used on the K-45.
To prevent serious injury, use only the accessories
specifically designed and recommended for use
with the K-45, such as those listed below.

Catalog

No.

68917
89410
76817

98072

23908

Model

No.

C-6429

A-39AF

Description

K-39/45 Inner Drum
Carrying Case
C-6 Cable Kit Includes:
– C-6 

3

/

8

x 35 (10mm x 10.7m) Cable

w/Inner Drum

– Torque Arm
– T-250 5 Piece Tool Kit
C-6IC Cable Kit Includes:
–  C-6IC 

3

/

8

x 35 (10mm x 10.7m) Cable

w/Inner Drum

– Torque Arm
– T-250 5 Piece Tool Kit
Drum front and AUTOFEED Assembly,
Replacement AUTOFEED Cartridge

Accessories

WARNING

Catalog

No. 

50647
50652
50657

62225
56782
89400
56792
95847

62235
56787

89405
56797

62245
62250
62260
96037

Model

No.

S-1
S-2
S-3

C-1

C-1IC

C-21

C-13IC

C-13ICSB

C-2

C-2IC

C-22

C-23IC

C-4
C-5
C-6

C-61C

Cables

5/16 (8mm)

Bulb Auger

Description

15' (4.6m) with Bulb Auger
25' (7.6m) with Bulb Auger
35' (10.7m) with Bulb Auger

25' (7.6m) w/Bulb Auger
25' (7.6m) Inner Core w/Bulb Auger
50' (15.2m) w/Bulb Auger
35' (10.7m) w/Bulb Auger
35' (10.7m) Inner Core Speed Bump
w/Bulb Auger

25' (7.6m) w/Drop Head Auger
25' (7.6m) Inner Core w/Drop

Head Auger

50' (15.2m) w/Drop Head Auger
35' (10.7m) w/Drop Head Auger

25' (7.6m) w/Male Coupling
35' (10.7m) w/Bulb Auger
35' (10.7m) w/Male Coupling
35' (10.7m) w/Male Coupling

5/16 (8mm)

Drop Head

3/8 (10mm)

1/4 (6mm)

Bulb Auger

Catalog

Model

No.

No.

Description

41937

— 

RIDGID Drain Cleaning 
Gloves, Leather

70032

RIDGID Drain Cleaning 
Gloves, PVC

62067

T-201A

Straight Flex Auger

62990

T-201

Straight Auger, 5" (12.5cm) Long

62995

T-202

Bulb Auger, 1

1

/

8

" (29mm) O.D.

63000

T-203

Bulb Auger, 

7

/

8

" (22mm) O.D.

55457

T-225

Retrieving Auger

63065

T-217

Drop Head, 4" (100mm) Long

54837

T-204

“C” Cutter 1" (25mm) 

63005

T-205

“C” Cutter 1

3

/

8

" (35mm)

63010

T-206

Funnel Auger, 3" (75mm) Long

63030

T-210

Grease Cutter, 1" (25mm)

63035

T-211

Grease Cutter, 1

3

/

8

" (35mm)

63040

T-212

Grease Cutter, 1

3

/

4

" (45mm)

63045

T-213

4-Blade Cutter, 1" (25mm)

63050

T-214

4-Blade Cutter, 1

3

/

8

" (35mm)

63055

T-215

4-Blade Cutter, 1

3

/

4

" (45mm)

52812

T-230

H-D “C” Cutter, 2" (50mm)

52817

T-231

H-D “C” Cutter, 2

1

/

2

" (64mm)

48482

T-250

Tool Set includes: 
T-203, T-205, T-210, T217, A-13

Accessories and Tools That Fit C-4, C-6 and C-6IC Cables

www.calcert.com

[email protected]

1.888.610.7664

0

5

10

15

20

25

30

Summary of Contents for 0095691360236

Page 1: ...his Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury Drain Cleaner Man...

Page 2: ...tion Inspection 6 Machine and Work Area Set Up 7 Operating Instructions 8 Operation 9 Feeding The Cable Into The Drain 9 Maintenance Instructions 11 Cleaning 11 Cables 12 AUTOFEED 12 Changing Cables C...

Page 3: ...erial number which is located on nameplate Serial No WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in ele...

Page 4: ...tool in a damp location is un avoidable use a ground fault circuit interrupter GFCI protected supply Use of a GFCI reduces the risk of electric shock Safety Symbols In this operator s manual and on t...

Page 5: ...uch preventive safety measures re duce the risk of starting the power tool accidentally Store idle power tools out of the reach of children and do not allow persons unfamiliar with the pow er tool or...

Page 6: ...ather work gloves Do not use damaged gloves Do not allow the end of cable to stop turning while the machine is running This can overstress the cable and may cause twisting kinking or breaking of the c...

Page 7: ...damage a drain that is in good condi tion and properly designed constructed and maintained If the drain is in poor condition or has not been properly designed constructed and maintained the drain clea...

Page 8: ...eadability of the warning label see Figure 2 Any other condition which may prevent safe and normal operation If any problems are found do not use the drain cleaner until the problems have been repaire...

Page 9: ...be messy 6 Determine if the K 45 cable outlet can be placed within 6 15cm of the drain opening If not the drain opening will need to be extended using similar size pipe and fittings so that the K 45 c...

Page 10: ...install the tool to the end of the cable The T slot coupler allows the cutting tool to be snapped into the cable coupler As the cutting tool is installed make sure that the spring loaded plunger in t...

Page 11: ...refers to the cable ro tation and not to the direction of cable movement Do not rotate the cable in reverse except as specifi cally described in these instructions Running the drain cleaner in REV can...

Page 12: ...sition may cause the cable to kink or knot and prevent removal from the drain Minimize the amount of cable fed into the transition to prevent problems The cables are not attached to the inner drum Use...

Page 13: ...to the drum This can be done either with the cable rotating or not Rotating the cable while retrieving does a better job of cleaning the drain and makes retrieving the cable easier Do not expose more...

Page 14: ...th AUTOFEED levers and push the cable through the AUTOFEED 2 Remove screw from AUTOFEED hand grip using 3 16 allen wrench Figure 12A and remove the AUTO FEED mechanism Figure 12B Figure 12A Removing A...

Page 15: ...ble before proceeding Use caution when removing the cable from the package The cable is under tension and could strike the user 3 Add a 15 30 degree bend approximately 1 25 4mm from the drum end of th...

Page 16: ...iece Tool Kit Drum front and AUTOFEED Assembly Replacement AUTOFEED Cartridge Accessories WARNING Catalog No 50647 50652 50657 62225 56782 89400 56792 95847 62235 56787 89405 56797 62245 62250 62260 9...

Page 17: ...our local waste management authority for more information For EC Countries Do not dispose of elec trical equipment with household waste According to the European Guideline 2002 96 EC for Waste Electri...

Page 18: ...ult Circuit Interrupter GFCI Moisture in motor switch or on plug AUTOFEED full of debris AUTOFEED needs lubrication Cable not evenly distributed Do Not Force Cable Let the cutter do the work Use corre...

Page 19: ...or replace during the warranty period the product is still defective you can elect to receive a full refund of your purchase price What is not covered Failures due to misuse abuse or normal wear and t...