Standard and Mini SeeSnake Diagnostic Equipment
Kollmann
PROBLEM
PROBABLE FAULT LOCATION
Garbled or jumbled video
Lights, but no video
No video, no camera
lights
Video, but no lights
White screen
Noisy Picture – vertical
stripes on Monitor
screen
Chart 1 Troubleshooting
Horizontal or Vertical hold need adjustment
75 Ohm-High Z switch in wrong position (older CCUs)
Fault within camera, cables, or CCU
SeeSnake System cable connected when playing back VCR
Monitor Contrast and/or Brightness is turned down
Break in video carrying conductor (pin/socket #3) between Camera and CCU
Fault within camera or CCU
CCU or monitor screen switch is turned OFF
SeeSnake System Cable not fully plugged in, or loose connection in system
Fault in any sub-assembly
Dimmer turned down
Fault within camera head, LED section
Contrast and/or Brightness is improperly set
Camera exposed to excessive light
Camera Head overheated
If further assistance is needed, please
call RIDGE Tool Technical Service at
(800) 519-3456. Additional information
may be available at www.ridgid.com or
www.seesnake.com