Step 3. Setting Operation
13 14
9. TROUBLESHOOTING
Problem /Indication
Possible Causes
Suggested Solution
No LED Indicator illuminated
on regulator
Solar panel disconnection
Battery voltage maybe
less than 8V
Battery over Voltage
Confirm that Solar panel
and battery wire connections
are correct and tight
Measure battery voltage
with the multimeter. Min.8V
can start up the regulator
Check if battery voltage is
higher than OVD, and
disconnect the Solar panel
Battery over discharged
When the battery voltage
is restored to or above LVR
point(low voltage reconnect
voltage), the load will recover
①
Check loads connection
carefully and clear the fault.
②
Press the button or
restart the regulator.
Load over load
Battery is fully charged
①
Please reduce the number
of electric equipment.
②
Press the button or
restart the regulator.
Load short circuit
No LED Indicator illuminated
on regulator
Charging status LED indicator
flashing fast
LED1 flashing fast
Load status LED indicator
flashing fast
Load status LED indicator
slowly flashing
Overcharge light is on
1. Load ON/OFF Setting
When the regulator is powered on, press the button to control the load
output.NOTE: The USB will output when the load is on.
2. Battery Type Setting
Operation:
Step 1: Enter setting mode by pressing button for 5 seconds until the
battery status LEDs are flashing.
Step 2: Select the desired mode by pressing button.
Step 3: The mode will be saved automatically without any operation for 5
seconds and LED will stop flashing.
Battery Type Indicator
NOTE: "
○
"LED indicator on "×"LED indicator off
LED1
LED2
LED3
○
○
○
○
○
○
x
x
x
Battery type
SEALED/AGM
Gel
Flooded (Lead acid) (Default)
8. SPECIFICATIONS
CARAVAN PANEL
Part Number: TPS-105S-110W
Frame Type:
Aluminium
Solar Panel
Mono crystalline solar panel
Charger Type: Solar
12v Battery Clamps Length:
Not Included
12v Cigarette Outlet Length:
Not Included
The regulator will
automatically cut off the
charging circuit, do not
need other actions.