5.7 1-phase 5-wire electric motor (115-230 VAC)
•
Make sure that the configuration (RCB-A) on X3 (TRANSFORMER) agrees with the supply voltage!
•
Connect the electric motor (EM) to X2 (MOTOR).
•
If applicable, remove the jumper from X4 and connect EM to X4 (PTC)
•
If the unit has a built-in MPCB, make sure to
change
the standard 3-phase connections
to 1-phase
connections! The diagram of §5.5 (X1) must change to the diagram of §5.7 (X1, X2, MPCB).
•
Connect the supply voltage to the MPCB (if applicable)
or
X1 (MAINS), and PE (protective earth).
5.8 Limit switch (RSU/RLS)
Connect a limit switch (RSU/RLS) to X9 of the control board (A2). Refer to the diagram that follows.
Also refer to the product manual of the used Ridder motor-gearbox at
.
Control board A2
(Out)
(In)
(In)
8 x 1,5 mm²
3 x 1,5 mm²
YES
NO
Control board A2
Common
Sa
fe
ty
Sa
fe
ty s
wit
ches
Duty s
wit
ch
Duty s
wit
ch