Service Maintenance
To enable the machine for maintenance by the service technician, the meter-charge mode must be set to
“enabled” with SP5930.
The table below shows the PM items serviced by the service technician.
After completing a PM procedure, reset the PM counter for the replaced part with SP7-804.
Symbol key:
• C: Clean
• R: Replace
• L: Lubricate
• I: Inspect
Main unit
Item
90K
EM
Quantity
Remarks
Paper Feed
Paper Feed Roller
R
C
1
Clean with water
Friction Pad
R
C
1
Clean with water
Registration Roller
C
C
1
Clean with water
Bottom Plate Pad
C
C
1
Clean with water
Around the Drum
Transfer Roller
R
1
Fusing Unit and Paper Exit
Hot Roller
R
1
Pressure Roller
R
1
Hot Roller Strippers
R
3
Fusing Thermistor
R
C
1
Clean with alcohol if
necessary.
Bushings - Hot Roller
R
2
Bushings - Pressure Roller
R
2
2. Preventive Maintenance
18
2
Summary of Contents for S-P2
Page 1: ...Model S P2 Machine Code M001 SERVICE MANUAL September 2008 Subject to change ...
Page 2: ......
Page 12: ...10 ...
Page 15: ... Never place anything on the power cord Installation Requirements 13 1 ...
Page 22: ...2 Preventive Maintenance 20 2 ...
Page 36: ...3 Replacement and Adjustment 34 3 ...
Page 49: ...Main Motor 1 Left cover Left Cover 2 Main motor A x 4 x 1 Main Motor 47 3 ...
Page 54: ...3 Replacement and Adjustment 52 3 ...
Page 56: ...4 PSU fan with the bracket A x 1 x 2 5 PSU fan B x 2 3 Replacement and Adjustment 54 3 ...
Page 82: ...4 Troubleshooting 80 4 ...
Page 166: ...5 Service Tables 164 5 ...
Page 197: ... Any operation panel keys pressed Image Fusing and Paper Exit 195 6 ...
Page 207: ...Controller Specifications Controller Specifications 205 7 ...
Page 208: ...Controller Board 1 DDR DIMM I F 7 Specifications 206 7 ...