4. Release the harnesses [1] ( x2, x4).
5. Remove screws [2] and [3] from the left and right ends of the brace.
6. Pull off the brace [4] to expose the motor [5].
7. Mark the shaft and timing gear [1] with a black marker. (This will make it easier to reattach the
gear at reinstallation.)
8. Remove the e-ring [2] and pull off the gear.
9. Remove the motor screws [3].
1. Replacement and Adjustment
100
Summary of Contents for RB5020
Page 1: ...Ring Binder RB5020 Machine Code D737 SERVICE MANUAL V1 1 May 2015 ...
Page 11: ...10 ...
Page 20: ...Binder Unit Covers Binder Unit Covers Common Procedures 19 ...
Page 49: ...4 Remove 1 Spring x1 2 Sensor bracket x2 3 Sensor x1 x1 x3 1 Replacement and Adjustment 48 ...
Page 72: ...3 Remove the sensor bracket x1 4 Remove the sensor x1 x1 Sensors 71 ...
Page 76: ...6 Remove the panel 7 Remove the sensor bracket 1 x1 8 Remove the sensor x1 x1 x1 Sensors 75 ...
Page 78: ...4 Remove the sensor bracket 1 x2 5 Remove the sensor x x1 Sensors 77 ...
Page 80: ...5 Remove the sensor x1 x1 Sensors 79 ...
Page 103: ...7 Disconnect the harnesses and remove the motor x2 1 Replacement and Adjustment 102 ...